Predictors of Zero X-Ray Ablation for Supraventricular Tachycardias in a Nationwide Multicenter Experience
Authors:
- Antonio PaniAPAntonio Pani
- Belotti GiuseppinaBGBelotti Giuseppina
- Carlo BonannoCBCarlo Bonanno
- Maria Grazia BongiorniMBMaria Grazia Bongiorni
- Nicola BottoniNBNicola Bottoni
- Roberta BrambillaRBRoberta Brambilla
- Sergio De CegliaSCSergio De Ceglia
- Paolo Della BellaPBPaolo Della Bella
- Giovanni De VitoGVGiovanni De Vito
- Daniele MalaspinaDMDaniele Malaspina
- Endrj MenardiEMEndrj Menardi
- Velia NapoliVNVelia Napoli
- 1 March 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 11 (3) , e005592
Abstract
Background: This multicenter, prospective study evaluated the determinants of zero-fluoroscopy (ZFL) ablation of supraventricular tachycardias. Methods and Results: Four hundred thirty patients (215 male, 55.4±22.1 years) with indication to electrophysiological study or ablation of supraventricular tachycardias were enrolled. All participating physicians agreed to follow the as low as reasonably achievable policy. A procedure was defined as ZFL when no fluoroscopy was used. The total fluoroscopy time inversely correlated to the number of procedures previously performed by each operator since study start ( r =−0.112; P =0.02). Two hundred eighty-nine procedures (67.2%) were ZFL; multivariable analysis identified as predictors of ZFL: procedure after the 30th for each operator, compared with procedures up to the ninth ( P =0.011; hazard ratio, 3.49; 95% confidence interval [CI], 1.79–6.80); the type of arrhythmia ( P =0.031; electrophysiological study and atrioventricular nodal reentry tachycardia ablation having the highest probability of ZFL; hazard ratio, 6.87; 95% CI, 2.08–22.7 and hazard ratio, 2.02; 95% CI, 1.04–3.91, respectively); the operator’s ( P =0.002) and patient’s age ( P =0.009). Among operators, achievement of ZFL varied from 0% to 100%; 8 (22.8%) operators achieved ZFL in 75% of their procedures. The probability of ZFL increased by 2.8% (hazard ratio, 0.98; 95% CI, 0.97–0.99) as patient’s age decreased by 1 year. Acute procedural success was obtained in all cases. Conclusions: The use of 3-dimensional mapping system completely avoided the use of fluoroscopy in most cases, with very low fluoroscopy time in the remaining and high safety and effectiveness profiles. Achievement of ZFL was predicted by the type of arrhythmia, operator’s experience, and patient’s age.Keywords
This publication has 17 references indexed in Scilit:
- A Zero‐Fluoroscopy Approach to Cavotricuspid Isthmus Catheter Ablation: Comparative Analysis of Two Electroanatomical Mapping SystemsPacing and Clinical Electrophysiology, 2014
- Radiation exposure as an occupational hazardEuroIntervention, 2012
- “Near-zero” fluoroscopic exposure in supraventricular arrhythmia ablation using the EnSite NavX™ mapping system: personal experience and review of the literatureJournal of Interventional Cardiac Electrophysiology, 2011
- Radiological Protection in Fluoroscopically Guided Procedures Performed Outside the Imaging DepartmentAnnals of the ICRP, 2010
- Learning Curve for Zero‐Fluoroscopy Catheter Ablation of AVNRT: Early versus Late ExperiencePacing and Clinical Electrophysiology, 2010
- Occupational radiation doses in interventional cardiology: a 15-year follow-upBritish Journal of Radiology, 2006
- PATIENT DOSIMETRY FOR X RAYS USED IN MEDICAL IMAGINGJournal of the ICRU, 2005
- Electromagnetic Versus Fluoroscopic Mapping of the Inferior Isthmus for Ablation of Typical Atrial FlutterCirculation, 2000
- New Method for Nonfluoroscopic Endocardial Mapping in HumansCirculation, 1998
- ConferenceJACC, 1998