Measuring cell for studying the characteristics of partial discharges in gas defects of insulation
Open Access
- 22 July 2025
- journal article
- Published by Kazan State Power Engineering University in Power engineering: research, equipment, technology
- Vol. 27 (3) , 14-22
Abstract
The actuality of the study is to calculate the design of a cell to measure the characteristics of partial discharges (PD) occurring in gas defects within solid insulation. The size and volume of gas inclusions in the insulation are related to the PD characteristics that occur in these defects. Knowledge of the details of this relationship for defects of various sizes and shapes is necessary for proper diagnosis of the insulation condition of high voltage apparatuses and determination of their residual life. This connection is currently studied to an insufficient extent. The task of studying PDs is complicated by their small magnitude and the difficulty of separating PDs in gas defects from surface, corona PDs and extraneous random noises having a similar spectrum.Objective of the work is to create an experimental setup with a measuring cell in which there are no corona and surface PDs, which complicate obtaining reliable results when measuring PDs in gas pores of a dielectric.Methods. The calculation of the electric field strength in various cell designs by the finite element method in the ComSol-Multiphysice 6.0 program was used to solve the problem.Results. The paper describes the relevance of the topic, presents the results of calculation of electric field distribution at different configurations of highvoltage electrodes, the results of PD measurements in control (defect-free) samples and samples with defects. It is proved that in the proposed design of the cell there are no surface and corona PDs on the electrodes, which allows us to study the characteristics of PDs in gas defects of insulation. It is established that PDs in a gas defect occur in the first and third parts of each period of a sinusoid of industrial frequency at the same potential difference between the electrodes. No shift of the PD occurrence voltage, which was predicted due to the assumed residual charge on the cavern walls, was found.Keywords
This publication has 11 references indexed in Scilit:
- A review on analysis and modeling of electrical machine insulation systemCogent Engineering, 2024
- Radiometric Partial Discharge Detection: A ReviewEnergies, 2023
- Review on Detection and Analysis of Partial Discharge along Power CablesEnergies, 2021
- Partial Discharge Simulation of Air Gap Defects in Oil-Paper Insulation Paperboard of Converter Transformer under Different Ratios of AC–DC Combined VoltageEnergies, 2021
- New model of explanation for phase angle pattern of online partial discharge measurement in winding insulation of turbine generatorJournal of Electrical Engineering, 2021
- NEW METHOD OF DETERMINING SIZE AND PROVISION OF DEFECTS IN THE INSULATION OF WINDINGS OF STATOR OF TURBOGENERATORS AT MEASUREMENT OF PARTIAL DISCHARGES IN THEMPower engineering: research, equipment, technology, 2018
- Effect of surface charge distribution on the electric field in a void due to partial discharges2011
- Modeling of Partial Discharges from a Spherical Cavity within a Dielectric Material under Variable Frequency Electric Fields2008
- Air ionization in a near-critical electric fieldTechnical Physics, 2006
- Similarity laws for pulsed gas dischargesUspekhi Fizicheskih Nauk, 2006