Laser in situ Keratomileusis for the Correction of Hyperopia From +1.25 to +5.00 Diopters With the Technolas Keracor 117C Laser
Author:
- 2 March 2001
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 17 (2) , 113-122
Abstract
PURPOSE: To assess the efficacy, predictability, stability, and safety of laser in situ keratomileusis (LASIK) in patients with hyperopia and to evaluate the visual and refractive results of the procedure. METHODS: LASIK was performed on 85 eyes of 53 patients for correction of hyperopia, with a preoperative mean manifest spherical equivalent refraction of +3.31 ± 0.69 D (range, +1.25 to +5.00 D) and mean refractive astigmatism of +0.91 ± 1.06 D (range, 0 to +3.00 D). The Carriazo-Barraquer (Moria) manual microkeratome was used to create the corneal flap, and laser ablation was performed using the Technolas Keracor 117C excimer laser with an ablation zone diameter of 6.0 mm and a transition zone diameter to 9.0 mm. Follow-up was 12 months for all patients. RESULTS: Refraction was stable by 3 months after surgery. At 1 year after LASIK, the mean manifest spherical equivalent refraction was +0.43 ± 0.57 D (range, -1.25 to +2.00 D) and refractive astigmatism was reduced to a mean of 0.36 ± 0.30 D (range, 0 to 1.00 D). Fifty-two eyes (61.2%) had a manifest spherical equivalent refraction within ±0.50 D of emmetropia, and 76 eyes (89.4%) were within ±1.00 D. Uncorrected visual acuity was 20/20 in 21 eyes (24.7%) and 20/40 or better in 79 eyes (92.9%). Spectacle-corrected visual acuity was reduced by two lines in one eye (1.2%) and improved by two lines in five eyes (5.9%). There were no significant complications. CONCLUSION: LASIK was an effective, safe, and predictable procedure for the correction of hyperopia up to +5.00 D and hyperopic astigmatism up to +3.00 D with the Technolas Keracor 117C excimer laser. The large size of the corneal flap obtained by the Carriazo-Barraquer (Moria) manual microkeratome facilitated laser ablation entirely in the exposed corneal stromal bed. [J Refract Surg 2001;17:113-122]Keywords
This publication has 27 references indexed in Scilit:
- Results of laser in situ keratomileusis in hyperopic compound astigmatismJournal of Cataract & Refractive Surgery, 1999
- Laser in situ keratomileusis for hyperopiaJournal of Cataract & Refractive Surgery, 1998
- Hyperopia Correction by Noncontact Holmium.YAG Laser Thermal KeratoplastyOphthalmology, 1996
- Automated lamellar keratoplasty for the correction of hyperopiaJournal of Cataract & Refractive Surgery, 1995
- The Influence of Corneal Thickness and Corneal Curvature on Tonometry Readings after Corneal Refractive SurgeryEuropean journal of Implant and Refractive Surgery, 1995
- Clinical evaluation of hexagonal keratotomy for the treatment of primary hyperopiaJournal of Cataract & Refractive Surgery, 1995
- Complications of Hexagonal KeratotomyAmerican Journal of Ophthalmology, 1994
- Magnification and Visual Acuity in Refractive SurgeryArchives of Ophthalmology (1950), 1993
- A Corneal Flap Technique for Laser In Situ KeratomileusisArchives of Ophthalmology (1950), 1991
- Hyperopic thermokeratoplasty: Clinical evaluationJournal of Cataract & Refractive Surgery, 1991