Automated bone segmentation from large field of view 3D MR images of the hip joint
Authors:
- Ying XiaYXYing Xia
- Jurgen FrippJFJurgen Fripp
- Shekhar S ChandraSCShekhar S Chandra
- Raphael SchwarzRSRaphael Schwarz
- Craig EngstromCECraig Engstrom
- Stuart CrozierSCStuart Crozier
- 27 September 2013
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (20) , 7375-7390
Abstract
Accurate bone segmentation in the hip joint region from magnetic resonance (MR) images can provide quantitative data for examining pathoanatomical conditions such as femoroacetabular impingement through to varying stages of osteoarthritis to monitor bone and associated cartilage morphometry. We evaluate two state-of-the-art methods (multi-atlas and active shape model (ASM) approaches) on bilateral MR images for automatic 3D bone segmentation in the hip region (proximal femur and innominate bone). Bilateral MR images of the hip joints were acquired at 3T from 30 volunteers. Image sequences included water-excitation dual echo stead state (FOV 38.6 × 24.1 cm, matrix 576 × 360, thickness 0.61 mm) in all subjects and multi-echo data image combination (FOV 37.6 × 23.5 cm, matrix 576 × 360, thickness 0.70 mm) for a subset of eight subjects. Following manual segmentation of femoral (head-neck, proximal-shaft) and innominate (ilium+ischium+pubis) bone, automated bone segmentation proceeded via two approaches: (1) multi-atlas segmentation incorporating non-rigid registration and (2) an advanced ASM-based scheme. Mean inter- and intra-rater reliability Dice's similarity coefficients (DSC) for manual segmentation of femoral and innominate bone were (0.970, 0.963) and (0.971, 0.965). Compared with manual data, mean DSC values for femoral and innominate bone volumes using automated multi-atlas and ASM-based methods were (0.950, 0.922) and (0.946, 0.917), respectively. Both approaches delivered accurate (high DSC values) segmentation results; notably, ASM data were generated in substantially less computational time (12 min versus 10 h). Both automated algorithms provided accurate 3D bone volumetric descriptions for MR-based measures in the hip region. The highly computational efficient ASM-based approach is more likely suitable for future clinical applications such as extracting bone-cartilage interfaces for potential cartilage segmentation.Keywords
This publication has 29 references indexed in Scilit:
- Automated detection, 3D segmentation and analysis of high resolution spine MR images using statistical shape modelsPhysics in Medicine & Biology, 2012
- Automatic graph-cut based segmentation of bones from knee magnetic resonance images for osteoarthritis researchMedical Image Analysis, 2011
- Robust statistical shape models for MRI bone segmentation in presence of small field of viewMedical Image Analysis, 2011
- Inter-subject comparison of MRI knee cartilage thicknessMedical Image Analysis, 2008
- MR measurement of articular cartilage thickness distribution in the hipOsteoarthritis and Cartilage, 2006
- Three-dimensional computed tomography of the hip in the assessment of femoroacetabular impingementJournal of Orthopaedic Research, 2005
- Three-dimensional distribution of acetabular cartilage thickness in patients with hip dysplasia: a fully automated computational analysis of MR imagingOsteoarthritis and Cartilage, 2004
- Active Shape Models-Their Training and ApplicationComputer Vision and Image Understanding, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945