Abstract
Accurate glycemic control (AGC) is difficult due to excessive hypoglycemia risk. Stochastic TARgeted (STAR) glycemic control forecasts changes in insulin sensitivity to calculate a range of glycemic outcomes for an insulin intervention, creating a risk framework to improve safety and performance. An improved, simplified STAR framework was developed to reduce light hypoglycemia and clinical effort, while improving nutrition rates and performance. Blood glucose (BG) levels are targeted to 80-145 mg/dL, using insulin and nutrition control for 1-3 h interventions. Insulin changes are limited to +3U/h and nutrition to ±30% of goal rate (minimum 30%). All targets and rate change limits are clinically specified and generalizable. Clinically validated virtual trials were run on using clinical data from 371 patients (39841 h) from the Specialized Relative Insulin and Nutrition Tables (SPRINT) cohort. Cohort and per-patient results are compared to clinical SPRINT data, and virtual trials of three published protocols. Performance was measured as time within glycemic bands, and safety by patients with severe (BG <; 40 mg/dL) and mild (%BG <; 72 mg/dL) hypoglycemia. Pilot trial results from the first ten patients (1486 h) are included to support the in-silico findings. In both virtual and clinical trials, mild hypoglycemia was below 2% versus 4% for SPRINT. Severe hypoglycemia was reduced from 14 (SPRINT) to 6 (STAR), and 0 in the pilot trial. AGC was tighter than both SPRINT clinical data and in-silico comparison protocols, with 91% BG within the specified target (80-145 mg/dL) in virtual trials and 89.4% in pilot trials. Clinical effort (measurements) was reduced from 16.2/day to 11.8/day (13.5/day in pilot trials). This STAR framework provides safe AGC with significant reductions in hypoglycemia and clinical effort due to stochastic forecasting of patient variation - a unique risk-based approach. Initial pilot trials validate the in-silico design methods and resulting protocol, all of which can be generalized to suit any given clinical environment.Keywords
This publication has 32 references indexed in Scilit:
- Pilot proof of concept clinical trials of Stochastic Targeted (STAR) glycemic controlAnnals of Intensive Care, 2011
- Organ failure and tight glycemic control in the SPRINT studyCritical Care, 2010
- Validation of a model-based virtual trials method for tight glycemic control in intensive careBioMedical Engineering OnLine, 2010
- The impact of early hypoglycemia and blood glucose variability on outcome in critical illnessCritical Care, 2009
- American Association of Clinical Endocrinologists and American Diabetes Association Consensus Statement on Inpatient Glycemic ControlDiabetes Care, 2009
- Intensive versus Conventional Glucose Control in Critically Ill PatientsThe New England journal of medicine, 2009
- Intensive insulin therapy and mortality among critically ill patients: a meta-analysis including NICE-SUGAR study dataCanadian Medical Association Journal, 2009
- Implementation and evaluation of the SPRINT protocol for tight glycaemic control in critically ill patients: a clinical practice changeCritical Care, 2008
- Effect of an Intensive Glucose Management Protocol on the Mortality of Critically Ill Adult PatientsMayo Clinic Proceedings, 2004
- Association Between Hyperglycemia and Increased Hospital Mortality in a Heterogeneous Population of Critically Ill PatientsMayo Clinic Proceedings, 2003