Non‐invasive assessment of peri‐implant mucosal thickness: A cross‐sectional study
Open Access
- 18 June 2023
- journal article
- research article
- Published by Wiley in Journal of Periodontology
- Vol. 94 (11) , 1315-1323
Abstract
Background: This study aimed to evaluate the reliability and reproducibility of different non‐invasive methods for the assessment of peri‐implant mucosal thickness.Methods: Subjects with two adjacent dental implants in the central maxillary region were included in this study. Three different methods to assess facial mucosal thickness (FMT) were compared: digital file superimposition using Digital Imaging and Communication in Medicine (DICOM) and stereolithography (STL) files of the arch of interest (DICOM‐STL), DICOM files alone, and non‐ionizing ultrasound (US). Inter‐rater reliability agreements between different assessment methods were analyzed using inter‐class correlation coefficients (ICCs).Results: A total of 50 subjects with 100 bone‐level implants constituted the study population. Assessment of FMT using STL and DICOM files demonstrated excellent inter‐rater reliability agreement. Mean ICC values of 0.97 and 0.95 were observed in the DICOM‐STL and DICOM groups, respectively. Comparison between the DICOM‐STL and US revealed good agreement, with an ICC of 0.82 (95% CI: 0.74 to 0.88) and a mean difference of –0.13 ± 0.50 mm (–1.13 to 0.86). Comparison between DICOM files alone versus US showed good agreement, with an ICC of 0.81 (95% CI: 0.73 to 0.89) and a mean difference of –0.23 ± 0.46 mm (–1.12 to 0.67). Comparison between DICOM‐STL and DICOM files revealed excellent agreement, with an ICC of 0.94 (95% CI: 0.91 to 0.96) and a mean difference of 0.1 ± 0.29 mm (LOA –0.47 to 0.46).Conclusions: Quantification of peri‐implant mucosal thickness via analysis of DICOM‐STL files, DICOM files, or US assessment are comparably reliable and reproducible methods.Keywords
This publication has 39 references indexed in Scilit:
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Non‐ionizing real‐time ultrasonography in implant and oral surgery: A feasibility studyClinical Oral Implants Research, 2016
- Four Modalities of Single Implant Treatment in the Anterior Maxilla: A Clinical, Radiographic, and Aesthetic EvaluationClinical Implant Dentistry and Related Research, 2012
- The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissuesClinical Oral Implants Research, 2011
- On cone‐beam computed tomography artifacts induced by titanium implantsClinical Oral Implants Research, 2009
- The gingival biotype assessed by experienced and inexperienced cliniciansJournal of Clinical Periodontology, 2009
- The gingival biotype revisited: transparency of the periodontal probe through the gingival margin as a method to discriminate thin from thick gingivaJournal of Clinical Periodontology, 2009
- Repeatability of ultrasonic determination of gingival thicknessClinical Oral Investigations, 2007
- The microbiota associated with successful or failing osseointegrated titanium implantsOral Microbiology and Immunology, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986