Enhanced Electrochemical Response of Diclofenac at a Fullerene–Carbon Nanofiber Paste Electrode
Open Access
Abstract
The requirements of the Water Framework Directive to monitor diclofenac (DCF) concentration in surface water impose the need to find advanced fast and simple analysis methods. Direct voltammetric/amperometric methods could represent efficient and practical solutions. Fullerene–carbon nanofibers in paraffin oil as a paste electrode (F–CNF) was easily obtained by simple mixing and tested for DCF detection using voltammetric and amperometric techniques. The lowest limit of detection of 0.9 nM was achieved by applying square-wave voltammetry operated under step potential (SP) of 2 mV, modulation amplitude (MA) of 10 mV, and frequency of 25 Hz, and the best sensitivity was achieved by four-level multiple pulsed amperometry (MPA) that allowed in situ reactivation of the F–CNF electrode. The selection of the method must take into account the environmental quality standard (EQS), imposed through the “watchlist” of the Water Framework Directive as 0.1 µg·L−1 DCF. A good improvement of the electroanalytical parameters for DCF detection on the F–CNF electrode was achieved by applying the preconcentration step for 30 min before the detection step, which assured about 30 times better sensitivity, recommending its application for the monitoring of trace levels of DCF. The electrochemical behavior of F–CNF as a pseudomicroelectrode array makes it suitable for practical application in the in situ and real-time monitoring of DCF concentrations in water.Keywords
This publication has 26 references indexed in Scilit:
- Electrochemical Determination of Diclofenac Sodium in Aqueous Solution on Cu‐Doped Zeolite‐Expanded Graphite‐Epoxy ElectrodeElectroanalysis, 2010
- Highly Selective and Sensitive Detection of Dopamine in the Presence of Excessive Ascorbic Acid Using Electrodes Modified with C60‐Functionalized Multiwalled Carbon Nanotube FilmsElectroanalysis, 2009
- Voltammetric study of fullerene C60 and fullerene C60 nanotubes with sandwich methodSynthetic Metals, 2009
- Voltammetric Detection of Urea on an Ag-Modified Zeolite-Expanded Graphite-Epoxy Composite ElectrodeSensors, 2008
- Significantly Accelerated Direct Electron‐Transfer Kinetics of Hemoglobin in a C60‐MWCNT Nanocomposite FilmChemistry – A European Journal, 2006
- Fatal medicine for vulturesNature, 2004
- Diclofenac residues as the cause of vulture population decline in PakistanNature, 2004
- Electrocatalytic Properties and Sensor Applications of Fullerenes and Carbon NanotubesElectroanalysis, 2003
- Pulsed electrochemical detection at noble metal electrodes in liquid chromatographyElectroanalysis, 1992
- Diffusion coefficients of ferri- and ferrocyanide ions in aqueous media, using twin-electrode thin-layer electrochemistryAnalytical Chemistry, 1970