Development of a five-plex flow cytometric immunoassay for the simultaneous detection of six coccidiostats in feed and eggs
Open Access
- 1 August 2012
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 404 (5) , 1361-1373
Abstract
Coccidiostats are the only veterinary drugs still permitted to be used as feed additives to treat poultry for coccidiosis. To protect consumers, maximum levels for their presence in food and feed have been set by the European Union (EU). To monitor these coccidiostats, a rapid and inexpensive screening method would be a useful tool. The development of such a screening method, using a flow cytometry-based immunoassay, is described. The assay uses five sets of colour-coded paramagnetic microspheres for the detection of six selected priority coccidiostats. Different coccidiostats, with and without carrier proteins, were covalently coupled onto different bead sets and tested in combination with polyclonal antisera and with a fluorescent-labelled secondary antibody. The five optimal combinations were selected for this multiplex and a simple-to-use sample extraction method was applied for screening blank and spiked eggs and feed samples. A very good correlation (r ranging from 0.995 to 0.999) was obtained with the responses obtained in two different flow cytometers (Luminex 100 and FLEXMAP 3D). The sensitivities obtained were in accordance with the levels set by the EU as the measured limits of detection for narasin/salinomycin, lasalocid, diclazuril, nicarbazin (4,4′-dinitrocarbanilide) and monensin in eggs were 0.01, 0.1, 0.5, 53 and 0.1 μg/kg and in feed 0.1, 0.2, 0.3, 9 and 1.5 μg/kg, respectively.Keywords
This publication has 37 references indexed in Scilit:
- Multiplex Screening of Persistent Organic Pollutants in Fish Using Spectrally Encoded MicrospheresAnalytical Chemistry, 2011
- Determination of eleven coccidiostats in animal feed by liquid chromatography–tandem mass spectrometry at cross contamination levelsAnalytica Chimica Acta, 2011
- Determination of ionophore coccidiostats in feeding stuffs by liquid chromatography–tandem mass spectrometry. Part II. Application to cross-contamination levels and non-targeted feedJournal of Pharmaceutical and Biomedical Analysis, 2011
- Development of a multiplex flow cytometric microsphere immunoassay for mycotoxins and evaluation of its application in feedMycotoxin Research, 2010
- Flow cytometric immunoassay for sulfonamides in raw milkAnalytica Chimica Acta, 2008
- Rapid time-resolved fluoroimmunoassay for the screening of monensin residues in eggsAnalytica Chimica Acta, 2005
- Rapid screening of narasin residues in poultry plasma by time-resolved fluoroimmunoassayAnalytica Chimica Acta, 2005
- Surface plasmon resonance biosensor screening of poultry liver and eggs for nicarbazin residuesAnalytica Chimica Acta, 2003
- Monoclonal-based enzyme-linked immunosorbent assay and immunochromatographic rapid assay for salinomycinAnalytica Chimica Acta, 2001
- Pharmacokinetic profile and tissue distribution of monensin in broiler chickensBritish Poultry Science, 1993