Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis
- 7 December 2012
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- Vol. 43 (5) , 558-567
Abstract
Background The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEOTM is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. Objective To evaluate the potential of VEOTM on diagnostic image quality and dose reduction in pediatric chest CT examinations. Materials and methods Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDIvol 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. Results At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. Conclusions At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection.Keywords
This publication has 25 references indexed in Scilit:
- Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image spaceClinical Radiology, 2011
- Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot StudyRadiology, 2011
- Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 PatientsAmerican Journal of Roentgenology, 2010
- Low-Tube-Voltage, High-Tube-Current Multidetector Abdominal CT: Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm—Initial Clinical ExperienceRadiology, 2010
- Innovations in CT Dose Reduction Strategy: Application of the Adaptive Statistical Iterative Reconstruction AlgorithmAmerican Journal of Roentgenology, 2010
- Radiation Dose Reduction With Chest Computed Tomography Using Adaptive Statistical Iterative Reconstruction TechniqueJournal of Computer Assisted Tomography, 2010
- State of the art: technologies for computed tomography dose reductionEmergency Radiology, 2009
- Pediatric Chest MDCT Using Tube Current Modulation: Effect on Radiation Dose with Breast ShieldingAmerican Journal of Roentgenology, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CTAmerican Journal of Roentgenology, 2001