Abstract
The technologies with kilovoltage (kV) and megavoltage (MV) imaging in the treatment room are now available for image‐guided radiation therapy to improve patient setup and target localization accuracy. However, development of strategies to efficiently and effectively implement these technologies for patient treatment remains challenging. This study proposed an aggregated technique for on‐board CT reconstruction using combination of kV and MV beam projections to improve the data acquisition efficiency and image quality. These projections were acquired in the treatment room at the patient treatment position with a new kV imaging device installed on the accelerator gantry, orthogonal to the existing MV portal imaging device. The projection images for a head phantom and a contrast phantom were acquired using both the On‐Board Imager™ kV imaging device and the MV portal imager mounted orthogonally on the gantry of a Varian Clinac™ 21EX linear accelerator. MV projections were converted into kV information prior to the aggregated CT reconstruction. The multilevel scheme algebraic‐reconstruction technique was used to reconstruct CT images involving either full, truncated, or a combination of both full and truncated projections. An adaptive reconstruction method was also applied, based on the limited numbers of kV projections and truncated MV projections, to enhance the anatomical information around the treatment volume and to minimize the radiation dose. The effects of the total number of projections, the combination of kV and MV projections, and the beam truncation of MV projections on the details of reconstructed kV/MV CT images were also investigated.Keywords
This publication has 33 references indexed in Scilit:
- A technique of intensity‐modulated radiosurgery (IMRS) for spinal tumorsMedical Physics, 2002
- A performance comparison of flat‐panel imager‐based MV and kV cone‐beam CTMedical Physics, 2002
- On few‐view tomographic reconstruction with megavoltage photon beamsMedical Physics, 2001
- Three‐dimensional computed tomographic reconstruction using a C‐arm mounted XRII: Image‐based correction of gantry motion nonidealitiesMedical Physics, 2000
- A room‐based diagnostic imaging system for measurement of patient setupMedical Physics, 1998
- A dual computed tomography linear accelerator unit for stereotactic radiation therapy: a new approach without cranially fixated stereotactic framesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- Dual-beam imaging for online verification of radiotherapy field placementInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995
- Cone-beam CT for radiotherapy applicationsPhysics in Medicine & Biology, 1995
- Radiotherapeutic computed tomography with scanned photon beamsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1987
- A Localising Device for a Rotating Cobalt Therapy UnitBritish Journal of Radiology, 1958