Using NU-KNIT® for hemostasis around recurrent laryngeal nerve during transthoracic esophagectomy with lymphadenectomy for esophageal cancer
Authors:
- Yasushi RinoYRYasushi Rino
- Norio YukawaNYNorio Yukawa
- Tsutomu SatoTSTsutomu Sato
- Naoto YamamotoNYNaoto Yamamoto
- Hiroshi TamagawaHTHiroshi Tamagawa
- Shinichi HasegawaSHShinichi Hasegawa
- Takashi OshimaTOTakashi Oshima
- Takaki YoshikawaTYTakaki Yoshikawa
- Munetaka MasudaMMMunetaka Masuda
- Toshio ImadaTIToshio Imada
Open Access
- 6 March 2014
- journal article
- research article
- Published by Springer Nature in BMC Research Notes
- Vol. 7 (1) , 127
Abstract
We thought that using electrocautery for hemostasis caused recurrent laryngeal nerve palsy. We reflected the prolonged use of electrocautery and employed NU-KNIT® to achieve hemostasis nearby the recurrent laryngeal nerve. We assessed that using NU-KNIT® hemostasis prevented or not postoperative recurrent laryngeal nerve palsy, retrospectively. The present study was evaluated to compare using electrocautery hemostasis with using NU-KNIT® hemostasis during lymphadenectomy along recurrent laryngeal nerve. The variables compared were morbidity rate of recurrent laryngeal nerve palsy, operation time, and blood loss. We use NU-KNIT® to achieve hemostasis without strong compression. This group is named group N. On the other hand, we use electrocautery to achieve hemostasis. This group is named group E. Complication rate of recurrent laryngeal nerve palsy was higher in group E (55.6%) than group N (5.3%) (p = 0.007). Even hemostasis using NU-KNIT® was slightly more time-consuming than using electrocautery, we concluded that it would be useful to prevent recurrent laryngeal nerve palsy.Keywords
This publication has 8 references indexed in Scilit:
- Reinforcing the Staple Line with Surgicel® Nu-knit® in Roux-en-Y Gastric Bypass: Comparison with Bovine Pericardial StripsObesity Surgery, 2013
- Hemostasis of the liver, spleen, and bone achieved by electrocautery greased with lidocaine gelSurgery Today, 2011
- [The use of oxygenated regenerated cellulose for hemostasis in cardiac surgery].2009
- Hand-Sewn Cervical Anastomosis Versus Stapled Intrathoracic Anastomosis After Esophagectomy for Middle or Lower Thoracic Esophageal Cancer: A Prospective Randomized Controlled StudySurgery Today, 2007
- Selective three-field lymphadenectomy for thoracic esophageal squamous carcinomaDiseases of the Esophagus, 2007
- Surgicel Nu-Knit hemostat for bleeding control of fragile sternumThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Superiority of electrocautery over the suture method for achieving cervical cone bed hemostasisObstetrics & Gynecology, 2003
- Superiority of Electrocautery Over the Suture Method for Achieving Cervical Cone Bed HemostasisObstetrics & Gynecology, 2003