Technical aspects of combined intrasaccular and endoluminal flow diversion
- 29 November 2020
- journal article
- research article
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 27 (3) , 346-352
Abstract
Introduction: The concurrent use of endoluminal flow diversion with coils is a viable option when treating complex or large aneurysms. Alternatives to coil embolization as an adjunctive treatment are currently limited. The Food and Drug Administration recently approved the Woven EndoBridge (WEB) device (Microvention, Aliso Viejo, California) as an intrasaccular flow diverter for wide-neck bifurcation aneurysms. We present the technical aspects of combined WEB device plus endoluminal flow diversion for the treatment of complex wide-necked intracranial aneurysms. Methods: A retrospective chart review of all patients treated via intrasaccular flow diversion at a single institution over the last 12 months was performed. Results: In total, seven patients underwent treatment of eight aneurysms via combined intrasaccular and endoluminal flow diversion. Of the seven patients, six were treated in a single setting. The most common aneurysm location was the posterior communicating artery. The majority of the aneurysms required steam shaping of the Via deployment catheter to place the WEB device orthogonally to the aneurysm dome. There were no complications. Conclusions: We believe this is one of the first series reporting the combined use of the WEB device and endoluminal flow diversion for the treatment of intracranial aneurysms. This series demonstrates that the concurrent use of the WEB device with endoluminal flow diversion is safe for achieving immediate aneurysm treatment and may enhance the long-term durability in complex aneurysms.Keywords
This publication has 19 references indexed in Scilit:
- Quantitative Assessment of In-Stent Stenosis After Pipeline Embolization Device Treatment of Intracranial Aneurysms: A Single-Institution Series and Systematic ReviewWorld Neurosurgery, 2018
- Wide-neck bifurcation aneurysms of the middle cerebral artery and basilar apex treated by endovascular techniques: a multicentre, core lab adjudicated study evaluating safety and durability of occlusion (BRANCH)Journal of NeuroInterventional Surgery, 2018
- The Combined Use of Intraluminal and Intrasaccular Flow Diversion for the Treatment of Intracranial Aneurysms: Report of 25 CasesNeurointervention, 2018
- Safety and efficacy of aneurysm treatment with WEB in the cumulative population of three prospective, multicenter seriesJournal of NeuroInterventional Surgery, 2017
- How safe and effective are existing treatments for wide-necked bifurcation aneurysms? Literature-based objective performance criteria for safety and effectivenessJournal of NeuroInterventional Surgery, 2017
- Endovascular techniques for the management of wide-neck intracranial bifurcation aneurysms: A critical review of the literatureJournal Of Neuroradiology, 2016
- Pipeline Embolization Device with or without Adjunctive Coil Embolization: Analysis of Complications from the IntrePED RegistryAmerican Journal of Neuroradiology, 2016
- Risk Factors for Hemorrhagic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the International Retrospective Study of the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2015
- International Retrospective Study of the Pipeline Embolization Device: A Multicenter Aneurysm Treatment StudyAmerican Journal of Neuroradiology, 2014
- Role of C-Arm VasoCT in the Use of Endovascular WEB Flow Disruption in Intracranial Aneurysm TreatmentAmerican Journal of Neuroradiology, 2014