Effect of smoke inhalation on viscoelastic properties and ventilation distribution in sheep
Authors:
- John F. FraserJFJohn F. Fraser
- Kimble DunsterKDKimble Dunster
- John FitzgibbonJFJohn Fitzgibbon
- Andreas SchiblerASAndreas Schibler
- 1 September 2006
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 101 (3) , 763-770
Abstract
Smoke inhalation injuries are the leading cause of mortality from burn injury. Airway obstruction due to mucus plugging and bronchoconstriction can cause severe ventilation inhomogeneity and worsen hypoxia. Studies describing changes of viscoelastic characteristics of the lung after smoke inhalation are missing. We present results of a new smoke inhalation device in sheep and describe pathophysiological changes after smoke exposure. Fifteen female Merino ewes were anesthetized and intubated. Baseline data using electrical impedance tomography and multiple-breath inert-gas washout were obtained by measuring ventilation distribution, functional residual capacity, lung clearance index, dynamic compliance, and stress index. Ten sheep were exposed to standardized cotton smoke insufflations and five sheep to sham smoke insufflations. Measured carboxyhemoglobin before inhalation was 3.87 ± 0.28% and 5 min after smoke was 61.5 ± 2.1%, range 50–69.4% ( P < 0.001). Two hours after smoke functional residual capacity decreased from 1,773 ± 226 to 1,006 ± 129 ml and lung clearance index increased from 10.4 ± 0.4 to 14.2 ± 0.9. Dynamic compliance decreased from 56.6 ± 5.5 to 32.8 ± 3.2 ml/cmH2O. Stress index increased from 0.994 ± 0.009 to 1.081 ± 0.011 ( P < 0.01) (all means ± SE, P < 0.05). Electrical impedance tomography showed a shift of ventilation from the dependent to the independent lung after smoke exposure. No significant change was seen in the sham group. Smoke inhalation caused immediate onset in pulmonary dysfunction and significant ventilation inhomogeneity. The smoke inhalation device as presented may be useful for interventional studies.Keywords
This publication has 21 references indexed in Scilit:
- The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjectsIntensive Care Medicine, 2005
- Pathophysiology of acute lung injury in combined burn and smoke inhalation injuryClinical Science, 2004
- Airway pressure-time curve profile (stress index) detects tidal recruitment/hyperinflation in experimental acute lung injuryCritical Care Medicine, 2004
- Measurement of lung volume in mechanically ventilated monkeys with an ultrasonic flow meter and the nitrogen washout methodIntensive Care Medicine, 2003
- Assessment of Severity of Ovine Smoke Inhalation Injury by Analysis of Computed Tomographic Scans2003
- A novel animal model of sepsis after acute lung injury in sheep*Critical Care Medicine, 2002
- Detection of local lung air content by electrical impedance tomography compared with electron beam CTJournal of Applied Physiology, 2002
- Measurement of Functional Residual Capacity in Rabbits and Children Using an Ultrasonic Flow MeterPediatric Research, 2001
- Effect of a Protective-Ventilation Strategy on Mortality in the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 1998
- Effects of wood and cotton smoke on the surface properties of pulmonary surfactantRespiration Physiology, 1994