Cardiac implantable electronic device-related endocarditis: A 12-year single-centre experience
- 25 July 2012
- journal article
- Published by Taylor & Francis in Scandinavian Journal of Infectious Diseases
- Vol. 44 (12) , 922-926
Abstract
Background: The incidence of cardiac implantable electrical device endocarditis (CIEDE) is increasing, but CIEDE remains a relatively poorly described infection. This case series describes our experience of the condition at a tertiary referral centre in London over a 12-y period. Methods: We identified cases using an endocarditis database containing prospectively collected clinical and microbiological information. We also used data recorded in an electronic database of all cardiac implantable electrical device-related procedures. Results: Thirty cases of CIEDE were treated at our institution during the study period. Presentation was most commonly with fever, and 93% of our patients had positive blood cultures. Vegetations were identified on echocardiography in only 70% of patients, although a transoesophageal echocardiogram (TOE) was performed in only half of the cases. Sixty-seven percent of our cases were defined as definite endocarditis according to the modified Duke criteria for infective endocarditis. Twenty-three patients underwent percutaneous explantation of their infected CIED (including 6 patients with vegetations greater than 10 mm in diameter), while 5 underwent surgical explantation. The overall in-hospital mortality was 17%. Conclusions: Our data confirm the life-threatening nature of CIEDE in a UK population. In addition, our experience suggests that percutaneous extraction of devices with large adherent vegetations may be safe, and that the selective use of TOE may not compromise outcomes. Lastly, we show that the modified Duke criteria do not perform very well with this condition, suggesting a need for specific, validated criteria for diagnosing CIEDE.Keywords
This publication has 11 references indexed in Scilit:
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Update on Cardiovascular Implantable Electronic Device Infections and Their ManagementCirculation, 2010
- Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient ManagementHeart Rhythm, 2009
- Pacemaker Endocarditis During 18 Years in GöteborgScandinavian Journal of Infectious Diseases, 2004
- Surgical Treatment of Pacemaker and Defibrillator Lead EndocarditisChest, 2003
- Successful Treatment of Pacemaker Related Endocarditis with Acute Embolic Stroke Without Device RemovalJournal of Interventional Cardiac Electrophysiology, 2003
- Pacemaker Related Endocarditis. Analysis of Seven Cases.Japanese Heart Journal, 2002
- Proposed Modifications to the Duke Criteria for the Diagnosis of Infective EndocarditisClinical Infectious Diseases, 2000
- Pacemaker infective endocarditisThe American Journal of Cardiology, 1998
- Systemic Infection Related to Endocarditis on Pacemaker LeadsCirculation, 1997