Abstract
This article presents a reconfigurable processor based on the alternating direction method of multipliers (ADMM) algorithm for reconstructing compressively sensed physiological signals. The architecture is flexible to support physiological ExG [electrocardiography (ECG), electromyography (EMG), and electroencephalography (EEG)] signal with various signal dimensions (128, 256, 384, and 512). Data characteristics are utilized to substantially reduce the overall hardware complexity by up to 99%. A 16x folded architecture achieves a 64% area-power product reduction compared with the unfolded one. A customized buffer is used for multi-word access, which reduces data latency by four times. It dissipates 75% less power with only 25% area when compared with the realization with conventional flip-flops. As a proof of concept, a reconfigurable processor for reconstructing ExG signals is presented. Fabricated in a 40-nm CMOS technology, the processor integrates 3.69-M gates in 3.23 mm². The chip delivers a throughput of 573-2901 kSamples/s (kS/s) for ExG signals and dissipates less than 12.6 mW at 87 MHz from a 0.60-V supply. Compared with state-of-the-art designs, the chip achieves a 1.5-to-14x higher throughput with 3.2-to-11x less energy, given the performance specification [reconstruction signal-to-noise ratio (RSNR) ≥ 15 dB].
Funding Information
  • Ministry of Science and Technology, Taiwan (MOST 106-2314-B-002-184)
  • National Taiwan University
  • NOVATEK Fellowship

This publication has 16 references indexed in Scilit: