Learning From Alarms: A Robust Learning Approach for Accurate Photoplethysmography-Based Atrial Fibrillation Detection Using Eight Million Samples Labeled With Imprecise Arrhythmia Alarms
- 1 February 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (5) , 2650-2661
Abstract
Atrial fibrillation (AF) is a common cardiac arrhythmia with serious health consequences if not detected and treated early. Detecting AF using wearable devices with photoplethysmography (PPG) sensors and deep neural networks has demonstrated some success using proprietary algorithms in commercial solutions. However, to improve continuous AF detection in ambulatory settings towards a population-wide screening use case, we face several challenges, one of which is the lack of large-scale labeled training data. To address this challenge, we propose to leverage AF alarms from bedside patient monitors to label concurrent PPG signals, resulting in the largest PPG-AF dataset so far (8.5M 30-second records from 24,100 patients) and demonstrating a practical approach to build large labeled PPG datasets. Furthermore, we recognize that the AF labels thus obtained contain errors because of false AF alarms generated from imperfect built-in algorithms from bedside monitors. Dealing with label noise with unknown distribution characteristics in this case requires advanced algorithms. We, therefore, introduce and open-source a novel loss design, the cluster membership consistency (CMC) loss, to mitigate label errors. By comparing CMC with state-of-the-art methods selected from a noisy label competition, we demonstrate its superiority in handling label noise in PPG data, resilience to poor-quality signals, and computational efficiency.Keywords
All Related Versions
Funding Information
- NIH (R01HL166233, K23HL125251, R01HL155711)
This publication has 40 references indexed in Scilit:
- Atrial fibrillation in the elderly population: Challenges and management considerationsJournal of Arrhythmia, 2021
- Negative-ResNet: noisy ambulatory electrocardiogram signal classification schemeNeural Computing and Applications, 2021
- Atrial fibrillation detection from raw photoplethysmography waveforms: A deep learning applicationHeart Rhythm O2, 2020
- Atrial Fibrillation Detection from Wrist Photoplethysmography Signals Using SmartwatchesScientific Reports, 2019
- Deep Bilevel Learning2018
- Can one detect atrial fibrillation using a wrist-type photoplethysmographic device?Medical & Biological Engineering & Computing, 2018
- Passive Detection of Atrial Fibrillation Using a Commercially Available SmartwatchJAMA Cardiology, 2018
- Empirical Risk Minimization2016
- Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveformJournal of Biomedical Informatics, 2008
- Silhouettes: A graphical aid to the interpretation and validation of cluster analysisJournal of Computational and Applied Mathematics, 1987