High‐frequency mode conversion technique for stiff lesion detection with magnetic resonance elastography (MRE)
Open Access
- 26 October 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (6) , 1457-1465
Abstract
A novel imaging technique is described in which the mode conversion of longitudinal waves is used for the qualitative detection of stiff lesions within soft tissue using magnetic resonance elastography (MRE) methods. Due to the viscoelastic nature of tissue, high‐frequency shear waves attenuate rapidly in soft tissues but much less in stiff tissues. By introducing minimally‐attenuating longitudinal waves at a significantly high frequency into tissue, shear waves produced at interfaces by mode conversion will be detectable in stiff regions, but will be significantly attenuated and thus not detectable in the surrounding soft tissue. This contrast can be used to detect the presence of stiff tissue. The proposed technique is shown to readily depict hard regions (mimicking tumors) present in tissue‐simulating phantoms and ex vivo breast tissue. In vivo feasibility is demonstrated on a patient with liver metastases in whom the tumors are readily distinguished. Preliminary evidence also suggests that quantitative stiffness measurements of stiff regions obtained with this technique are more accurate than those from conventional MRE because of the short shear wavelengths. This rapid, qualitative technique may lend itself to applications in which the localization of stiff, suspicious neoplasms is coupled with more sensitive techniques for thorough characterization. Magn Reson Med, 2009.Keywords
This publication has 20 references indexed in Scilit:
- MR Elastography of Liver Tumors: Preliminary ResultsAmerican Journal of Roentgenology, 2008
- Vibration safety limits for magnetic resonance elastographyPhysics in Medicine & Biology, 2008
- Liver Fibrosis: Noninvasive Assessment with MR Elastography versus Aspartate Aminotransferase–to-Platelet Ratio IndexRadiology, 2007
- MR elastography of breast lesions: Understanding the solid/liquid duality can improve the specificity of contrast‐enhanced MR mammographyMagnetic Resonance in Medicine, 2007
- Assessment of Hepatic Fibrosis With Magnetic Resonance ElastographyClinical Gastroenterology and Hepatology, 2007
- Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastographyNMR in Biomedicine, 2007
- Needle shear wave driver for magnetic resonance elastographyMagnetic Resonance in Medicine, 2006
- Viscoelastic shear properties of in vivo breast lesions measured by MR elastographyMagnetic Resonance Imaging, 2005
- Contrast-enhanced MRI of the breast: accuracy, value, controversies, solutionsEuropean Journal of Radiology, 1997
- Magnetic resonance imaging of transverse acoustic strain wavesMagnetic Resonance in Medicine, 1996