Study on Surface Rainwater and Arc Characteristics of High-Voltage Bushing With Booster Sheds Under Heavy Rainfall
Open Access
- 30 July 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 146865-146875
Abstract
The flashover performance of insulators can be improved by BS (booster sheds) in the rain, which is mainly attributed to the reasons that BS break up long cascades of water and block connections of arcs. However, surface rainwater characteristics and arc characteristics of bushing have not been quantitatively studied under heavy rainfall. In this paper, the artificial rain tests were conducted on a 500 kV transformer high-voltage bushing equipped with and without BS under the rainfall intensity of 10 mm/min. X (the total length of water column) and Larc (the critical length of arc) on the bushing surface were taken as the feature parameters of surface rainwater characteristics and arc characteristics, respectively. The effects of BS on Eh (the rain flashover voltage gradient along the insulation height), X and Larc were investigated, respectively. Furtherly, the relationships were studied among Eh, X and Larc. Results indicate that Eh has a sharp rise as the number of BS (NBS) is from one to two, however the rise of Eh gradually decreases when NBS exceeds two. X decreases while Larc increases with the rise of NBS, however both the change ranges of them continually fall. Furthermore, Larc presents remarkable negative correlation to X because of the effect of the electric field. Eh rises nonlinearly with the decrease of X, which is due to the change of the wetting uniformity on the bushing surface and the potential redistribution along air gaps in the presence of the local arc.Keywords
Funding Information
- Smart Grid Joint Fund Key Project between National Natural Science Foundation of China and State Grid Corporation (U1766220)
- Science and Technology Project of China Southern Power Grid (CSGTRC-K163024)
This publication has 23 references indexed in Scilit:
- Investigation of DC discharge behavior of polluted porcelain post insulator in artificial rainIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- External flashovers, related insulation failures and corrective measures in converter stations of Nelson River bipole 1 and bipole 2IEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Electrical performance evaluation of EHV post insulators covered with ice under different air gap configurationsIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Artificial pollution flashover performance of porcelain long rod UHVDC insulators at high altitudesIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Effect of water streams on the AC breakdown performance of short rod-plane air gapsIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Three-Dimensional Modeling of Potential and Electric-Field Distributions Along an EHV Ceramic Post Insulator Covered With Ice—Part II: Effect of Air Gaps and Partial ArcsIEEE Transactions on Power Delivery, 2005
- Flashover of contaminated nonceramic outdoor insulators in a wet atmosphereIEEE Transactions on Dielectrics and Electrical Insulation, 1998
- The AC-behavior of a hydrophilic and hydrophobic post insulator during rainIEEE Transactions on Power Delivery, 1994
- Modelling of HVDC wall bushing flashover in nonuniform rainIEEE Transactions on Power Delivery, 1991
- Laboratory tests to evaluate HVDC wall bushing performance in wet weatherIEEE Transactions on Power Delivery, 1990