Dissipation of charge on MALDI‐TOF polymeric chips using an electron‐acceptor: analysis of proteins
- 16 March 2007
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 42 (5) , 634-640
Abstract
Disposable polymeric devices used for direct sample pretreatment/signal enhancement and MALDI‐MS analyses of biomolecules suffer from the accumulation of electric charge and related positive mass shifts due to photoelectric effects on non‐conductive surfaces after irradiation with lasers. The effects of surface charging on the mass shift of protein spectra during MALDI‐TOF/MS measurements on copolymeric sample array chips were studied. Methyl viologen is used to monitor the development of charge and is demonstrated to be an effective electron scavenger. The use of such reducible species leads to increased accuracy, signal homogeneity, and resolution for mass spectral measurements of proteins in mixtures with sinapinic and 2,5‐dihydroxybenzoic (DHB) acids. This approach can be used on a wide range of nonconductive support materials. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 24 references indexed in Scilit:
- Complete Chemical and Enzymatic Treatment of Phosphorylated and Glycosylated Proteins on ProteinChip ArraysAnalytical Chemistry, 2005
- Direct MS/MS Analysis of Proteins Blotted on Membranes by a Matrix-Assisted Laser Desorption/Ionization-Quadrupole Ion Trap-Time-of-Flight Tandem Mass SpectrometerJournal of Proteome Research, 2005
- Quantitative Analysis in Nanoliter Wells by Prefilling of Wells Using Electrospray Deposition Followed by Sample Introduction with a Coverslip MethodAnalytical Chemistry, 2004
- Clinical proteomics: a question of technologyRapid Communications in Mass Spectrometry, 2004
- Electrowetting-Based Microfluidics for Analysis of Peptides and Proteins by Matrix-Assisted Laser Desorption/Ionization Mass SpectrometryAnalytical Chemistry, 2004
- Mass Spectral Analysis in ProteomicsAnnual Review of Biophysics, 2004
- Role of Electrons in Laser Desorption/Ionization Mass SpectrometryAnalytical Chemistry, 2003
- Disposable polymeric high-density nanovial arrays for matrix assisted laser desorption/ionization- time of flight-mass spectrometry: I. Microstructure development and manufacturingElectrophoresis, 2001
- Sensitivity and mass accuracy for proteins analyzed directly from polyacrylamide gels: Implications for proteome mappingElectrophoresis, 1997
- Poly(vinylidene difluoride) membranes as the interface between laser desorption mass spectrometry, gel electrophoresis, and in situ proteolysisAnalytical Chemistry, 1994