4D temperature measurements using tomographic two-color pyrometry

Authors:
  • TYTao Yu
    Tao Yu
  • FBFlorian J. Bauer
    Florian J. Bauer
  • FHFranz J. Huber
    Franz J. Huber
  • SWStefan Will
    Stefan Will
  • WCWeiwei Cai
    Weiwei Cai

Abstract
This work presents a new approach for high-speed four-dimensional (3D + t) thermometry using only two high-speed cameras which are equipped with different band pass filters to capture thermal radiation signals at two narrow wavelength bands. With the help of a customized fiber bundle and a beam splitter, a total number of nine projections at each band were recorded, and the temperature distribution was evaluated by tomographic two-color pyrometry. In order to validate the effectiveness of this method, the 3D temperature distribution of a premixed steady flat flame was evaluated. The determined temperatures were compared to those of other studies, as well as to the results from inverse Abel transform and line-of-sight data. Further, the 3D temperature evolution of a weakly turbulent diffusion flame was observed at a repetition rate of 7.5 kHz. Such 4D temperature measurements are expected to be valuable in understanding turbulent combustion mechanisms especially of practical devices.
Funding Information
  • China Scholarship Council
  • National Natural Science Foundation of China (51976122, 52061135108)
  • Erlangen Graduate School of Advanced Optical Technologies
  • National Major Science and Technology Projects of China (2017-III-0007-0033)

This publication has 44 references indexed in Scilit: