Parametric Finite Element Analyses of Demountable Shear Connection in Cold-Formed Steel–Concrete Composite Beams
Open Access
Abstract
It is known that steel–concrete composite systems are very efficient. However, such steel–concrete composite systems can be optimised using cold-formed steel elements and innovative shear connections. In other words, by considering demountability and reusability, the negative impact of the built environment on the whole ecosystem can ultimately be reduced. This paper, therefore, presents a numerical study of an innovative solution for a composite floor system consisting of built-up cold-formed sections and concrete slabs. Through parametric numerical analysis, parameters such as the diameter and quality of bolts, the concrete class, the type of concrete slab, and the steel quality of sections and bolts were varied. The numerical analysis results show that the system with a solid concrete slab had a higher shear resistance and ductility than the system with a concrete slab made with profiled sheeting and showed different failure modes. The presented results form the basis for push-out tests for the proposed shear connection types.Keywords
Funding Information
- Hrvatska Zaklada za Znanost (UIP-2020-02-2964)
This publication has 26 references indexed in Scilit:
- Effect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear ConnectorsJournal of Structural Engineering, 2015
- Experimental investigations of cold-formed steel beams of corrugated web and built-up section for flangesThin-Walled Structures, 2015
- New composite beams having cold-formed steel joists and concrete slabEngineering Structures, 2014
- Feasibility of developing composite action between concrete and cold-formed steel beamJournal of Central South University, 2013
- Bolted shear connectors vs. headed studs behaviour in push-out testsJournal of Constructional Steel Research, 2013
- Behavior of Concrete/Cold Formed Steel Composite Beams: Experimental Development of a Novel Structural SystemInternational Journal of Concrete Structures and Materials, 2013
- The influence of profiled sheeting thickness and shear connector’s position on strength and ductility of headed shear connectorEngineering Structures, 2011
- Test of shear transfer enhancement in symmetric cold-formed steel–concrete composite beamsJournal of Constructional Steel Research, 2009
- Experimental study of composite cold-formed steel C-section floor joistsJournal of Constructional Steel Research, 2006
- Tests of composite beams with cold-formed sectionsJournal of Constructional Steel Research, 2000