Reliability of pharmacokinetic parameters: Small vs. medium‐sized contrast agents
Open Access
- 21 July 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (3) , 779-787
Abstract
Current clinical applications of dynamic contrast‐enhanced MRI (DCE‐MRI) are based on the extravasation of relatively small contrast agents (SCAs). SCAs are considered disadvantageous, as they require high image sampling rates. Medium‐sized contrast agents (MCAs) leak more slowly into tissue and allow longer dynamic acquisition times, enabling improved image quality. The influence of molecular size on the reliability of pharmacokinetic parameters, including the transfer constant Ktrans, was investigated. Computer simulations were performed, with in vivo measured arterial input functions (AIFs), to determine the bias and variance of pharmacokinetic parameters as a function of contrast agent size, sampling frequency, noise level, and acquisition time. Better reliability of all parameters was obtained for the MCA compared to the SCA. To obtain similar variance (10%) in Ktrans, the sampling frequency for the SCA (28 min−1) had to be 20 times faster than for the MCA (1.3 min−1). Optimal reliability in parameter estimation required longer acquisition times for MCAs (13 min for the fraction of the extravascular extracellular space into which the contrast agent distributes (ve) and 5 min for Ktrans) than for SCAs (1.7 min for Ktrans and ve). Reliable estimation of the fractional blood plasma volume (vp) was only achieved with MCAs. In conclusion, MCAs provided superior reliability for pharmacokinetic parameter estimation compared to SCAs. Magn Reson Med, 2009.Keywords
This publication has 35 references indexed in Scilit:
- Incorporating a vascular term into a reference region model for the analysis of DCE-MRI data: a simulation studyPhysics in Medicine & Biology, 2008
- System identification theory in pharmacokinetic modeling of dynamic contrast‐enhanced MRI: Influence of contrast injectionMagnetic Resonance in Medicine, 2008
- Measurement of kinetic parameters in skeletal muscle by magnetic resonance imaging with an intravascular agentMagnetic Resonance in Medicine, 2006
- Magnetic Resonance Macromolecular Agents for Monitoring Tumor Microvessels and Angiogenesis InhibitionInvestigative Radiology, 2006
- Measurement of skeletal muscle perfusion during postischemic reactive hyperemia using contrast‐enhanced MRI with a step‐input functionMagnetic Resonance in Medicine, 2005
- Characterizing Extravascular Fluid Transport of Macromolecules in the Tumor Interstitium by Magnetic Resonance ImagingCancer Research, 2005
- Tumor microvascular changes in antiangiogenic treatment: Assessment by magnetic resonance contrast media of different molecular weightsJournal of Magnetic Resonance Imaging, 2004
- Longitudinal MRI tracking of the angiogenic response to hind limb ischemic injury in the mouseMagnetic Resonance in Medicine, 2004
- Comparison of albumin‐(Gd‐DTPA)30 and Gd‐DTPA‐24‐cascade‐polymer for measurements of normal and abnormal microvascular permeabilityJournal of Magnetic Resonance Imaging, 1997
- Differentiation of Spontaneous Canine Breast Tumors Using Dynamic Magnetic Resonance Imaging with 24-Gadolinium-DTPA-Cascade-Polymer, A New Blood-Pool AgentInvestigative Radiology, 1996