Can virtual non-contrast imaging replace true non-contrast imaging in multiphase scanning of the neck region?
Open Access
- 1 August 2023
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica Open
- Vol. 12 (8)
Abstract
Background: Dual-energy computed tomography (DECT) is an advanced imaging method that enables reconstruction of virtual non-contrast (VNC) images from a contrast-enhanced acquisition. This has the potential to reduce radiation exposure by eliminating the need for a true non-contrast (TNC) phase. Purpose: The purpose is to evaluate the feasibility of VNC images in the neck region. Materials and methods: A total of 100 patients underwent a DECT scan as part of diagnostic workup of primary hyperparathyroidism. VNC images were reconstructed from 30 s (arterial) and 50 s (venous) post-contrast scans. Regions of interest (ROIs) were placed in thyroid tissue, lymph node, carotid artery, jugular vein, fat, and sternocleidomastoid muscle. Mean densities of all anatomical structures were compared between VNC and TNC images. Results: For all anatomical structures except the thyroid gland, the difference in mean density between TNC and VNC images was less than 15 HU. The mean difference in density between TNC and VNC images of the thyroid was 53.2 HU (95% CI 46.8; 59.6, p = <0.001). Conclusion: This study demonstrated an acceptable agreement in density between true non-contrast and virtual non-contrast images for most anatomical structures in the neck region. Therefore, VNC images may have the potential to replace TNC images in the neck. However, due to significant differences in CT density of thyroid tissue, true non-contrast imaging cannot be directly substituted by virtual non-contrast imaging when examining the thyroid and its surrounding tissue.Keywords
Funding Information
- Siemens Healthineers (institutional grants Siemens healthineers, Bayer h)
This publication has 26 references indexed in Scilit:
- Incidental Findings in Abdominal Dual-Energy Computed TomographyJournal of Computer Assisted Tomography, 2017
- Detection of parathyroid adenomas using a monophasic dual-energy computed tomography acquisition: diagnostic performance and potential radiation dose reductionNeuroradiology, 2016
- Dual-Energy CT Characteristics of Parathyroid Adenomas on 25-and 55-Second 4D-CT AcquisitionsJournal of Computer Assisted Tomography, 2016
- Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck CancerEuropean Radiology, 2015
- 3-phase dual-energy CT scan as a feasible salvage imaging modality for the identification of non-localizing parathyroid adenomas: A prospective studyJournal of Otolaryngology - Head & Neck Surgery, 2015
- Dual-Energy CT Applications in Head and Neck ImagingAmerican Journal of Roentgenology, 2012
- Virtual unenhanced second generation dual-source CT of the liver: Is it time to discard the conventional unenhanced phase?European Journal of Radiology, 2012
- Iodine removal in intravenous dual-energy CT-cholangiography: Is virtual non-enhanced imaging effective to replace true non-enhanced imaging?European Journal of Radiology, 2012
- Parathyroid Four‐Dimensional Computed Tomography: Evaluation of Radiation Dose Exposure During Preoperative Localization of Parathyroid Tumors in Primary HyperparathyroidismWorld Journal of Surgery, 2011
- Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998Radiation Research, 2007