Noninvasive detection of temozolomide in brain tumor xenografts by magnetic resonance spectroscopy†
Open Access
- 20 October 2009
- journal article
- research article
- Published by Oxford University Press (OUP) in Neuro-Oncology
- Vol. 12 (1) , 71-79
Abstract
Poor drug delivery to brain tumors caused by aberrant tumor vasculature and a partly intact blood-brain barrier (BBB) and blood-brain tumor barrier (BTB) can significantly impair the efficacy of chemotherapy. Determining drug delivery to brain tumors is a challenging problem, and the noninvasive detection of drug directly in the tumor can be critically important for accessing, predicting, and eventually improving effectiveness of therapy. In this study, in vivo magnetic resonance spectroscopy (MRS) was used to detect an anticancer agent, temozolomide (TMZ), in vivo in murine xenotransplants of U87MG human brain cancer. Dynamic magnetic resonance imaging (MRI) with the low-molecular-weight contrast agent, gadolinium diethylenetriaminepentaacetic acid (GdDTPA), was used to evaluate tumor vascular parameters. Carbon-13-labeled TMZ ([13C]TMZ, 99%) was intraperitoneally administered at a dose of ∼140 mg/kg (450 mg/m2, well within the maximal clinical dose of 1000 mg/m2 used in humans) during the course of in vivo MRS experiments. Heteronuclear multiple-quantum coherence (HMQC) MRS of brain tumors was performed before and after i.p. administration of [13C]TMZ. Dynamic MRI experiments demonstrated slower recovery of MRI signal following an intravenous bolus injection of GdDTPA, higher vascular flow and volume obtained by T*2-weighted MRI, as well as enhanced uptake of the contrast agent in the brain tumor compared with normal brain detected by T1-weighted MRI. These data demonstrate partial breakdown of the BBB/BTB and good vascularization in U87MG xenografts. A [13C]TMZ peak was detected at 3.9 ppm by HMQC from a selected volume of about 0.15 cm3 within the brain tumor with HMQC pulse sequences. This study clearly demonstrates the noninvasive detection of [13C]TMZ in xenografted U87MG brain tumors with MRS. Noninvasive tracking of antineoplastic agents using MRS can have a significant impact on brain tumor chemotherapy.Keywords
This publication has 28 references indexed in Scilit:
- Comparison of Dynamic Susceptibility-weighted Contrast-enhanced MR Methods: Recommendations for Measuring Relative Cerebral Blood Volume in Brain TumorsRadiology, 2008
- Noninvasive 1H/13C magnetic resonance spectroscopic imaging of the intratumoral distribution of temozolomideMagnetic Resonance in Medicine, 2006
- Radiotherapy plus Concomitant and Adjuvant Temozolomide for GlioblastomaNew England Journal of Medicine, 2005
- Perfusion MRI of U87 brain tumors in a mouse modelMagnetic Resonance in Medicine, 2004
- Magnetic Resonance Imaging in Experimental Models of Brain DisordersJournal of Cerebral Blood Flow & Metabolism, 2003
- The effect of brain tumor angiogenesis on the in vivo relationship between the gradient‐echo relaxation rate change (ΔR2*) and contrast agent (MION) doseJournal of Magnetic Resonance Imaging, 2003
- Tracer arrival timing‐insensitive technique for estimating flow in MR perfusion‐weighted imaging using singular value decomposition with a block‐circulant deconvolution matrixMagnetic Resonance in Medicine, 2003
- Pharmacokinetics of the 13C labeled anticancer agent temozolomide detected in vivo by selective cross‐polarization transferMagnetic Resonance in Medicine, 1995
- Symmetric pulses to induce arbitrary flip angles with compensation for rf inhomogeneity and resonance offsetsJournal of Magnetic Resonance (1969), 1991
- Functional cerebral imaging by susceptibility‐contrast NMRMagnetic Resonance in Medicine, 1990