Correlation of some mechanical properties of embedding resins with their behaviour in microtomy
Authors:
- 1 May 1987
- journal article
- research article
- Published by Wiley in Journal of Electron Microscopy Technique
- Vol. 6 (1) , 63-79
Abstract
The technology of ultramicrotomy is now well established, but the properties of the resin that determine the different forces needed to generate a section have been neglected, although this process could introduce artefacts in the thin sections. We have investigated the principal resin dependent factors involved in the sectioning process and determined the related mechanical properties. Tensile experiments have given the best correlation with the sectioning quality of the resin: the elastic (Young's) modulus value (depending on polymer structure or hardening mode), the presence of a short plastic flow for a controlled fracture and enough flexibility to minimize shearing, and internal cracks, appear to be the main characteristic parameters. The ultrathin section seems to be generated by a process close to cleavage, favoured by the relative hardness of the embedding media, while machining and “true” sectioning requires softer resins.Consequently, the rupture follows the path of least resistance in the specimen‐resin composite, providing sections with a surface relief. Embedded biological material copolymerizes with polycondensed matrix (epoxy resins), and, by reducing the heterogeneity, gives smoother sections. Embedments hardened by radical polymerization provide a rougher relief, since almost no copolymerization occurs, offering to the microtome a heterogeneous block with two constituents of very different mechanical properties. The surface relief seems to be an important factor in labelling, staining, and imaging, and more attention has to be paid for some improvements of the quality of the information provided by electron microscopy.Keywords
This publication has 39 references indexed in Scilit:
- Ein beitrag zur frage welche kra¨fte und faktoren du¨nnstschneiden bewirkenJournal of Ultrastructure Research, 1985
- Heavy metal-containing surroundings provide much more “Negative” contrast by Z-imaging in stem than with conventional modesJournal of Ultrastructure Research, 1982
- Septate junction ultrastructure as visualized in unstained and stained preparationsJournal of Ultrastructure Research, 1982
- Pea seed storage proteins ? Immunocytochemical localization with protein a-gold by electron microscopyProtoplasma, 1981
- Fracture processes in polystyreneProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1975
- A low-viscosity epoxy resin embedding medium for electron microscopyJournal of Ultrastructure Research, 1969
- Mechanism of fracture in glassy polymers. IV. Temperature rise at the tip of propagating crack in poly(methyl methacrylate)Journal of Polymer Science Part A-2: Polymer Physics, 1966
- L'inclusion au polyester pour l'ultramicrotomieJournal of Ultrastructure Research, 1958
- A High Speed Microtome for the Electron MicroscopeReview of Scientific Instruments, 1946
- New Microtome and Sectioning Method for Electron MicroscopyScience, 1943