Patient‐Reported Outcomes After Use of a Bioabsorbable Collagen Implant to Treat Partial and Full‐Thickness Rotator Cuff Tears
- 23 July 2019
- journal article
- research article
- Published by Wiley in Arthroscopy
- Vol. 35 (8) , 2262-2271
Abstract
Purpose: To collect outcomes data on patients treated with a bioinductive collagen implant designed to induce rotator cuff healing in partial‐ and full‐thickness cuff tears and to assess the safety and efficacy of the device. Methods: Fifteen surgeons in 15 centers in the United States enrolled patients between April 2016 and August 2017 and collected standardized outcomes data. Patients 21 years of age and older, able to read and speak English, and with partial‐ or full‐thickness tears of the rotator cuff documented by magnetic resonance imaging were included in the study. Patients were assessed preoperatively with visual analogue scale (VAS), single‐assessment numeric evaluation (SANE), Veterans RAND 12‐Item (VR‐12), American Shoulder and Elbow Surgeons (ASES), and Western Ontario Rotator Cuff (WORC) outcomes measures. Postoperative assessment was made at 2, 6, and 12 weeks, 6 months, and 1 year. Patients underwent a standardized operative procedure with the implant. Patient demographics, comorbidities, tear types, and concomitant operative procedures were recorded. Results: Patients in both groups experienced statistically significant improvement in VAS, SANE, VR‐12 PCS, ASES, and WORC scores (mean values 1.1, P < .001; 86.0, P < .001; 49.7, P < .001; 85.6, P < .001; and 84.4, P < .001 for partial tears and 1.2, P < .001; 80.7, P < .001; 45.7, P < .001; 83.8, P < .0001; and 80.1, P < .001 for full‐thickness tears, respectively). For the partial tear group, average times for return to driving, work, and nonoverhead athletic activity were 14.6, 37.3, and 65.6 days, and for the full‐thickness group, 24.5, 50.7, and 119.2 days, respectively. In the partial‐thickness group, 84% and 83% of patients reported improvement in their VAS pain and ASES scores, respectively, that met or exceeded each measure's minimal clinically important difference. In the full‐thickness group, 72% and 77% of the patients met or exceeded the minimal clinically important differences for VAS pain and ASES, respectively. Conclusion: Outcomes after repair of partial‐ and full‐thickness rotator cuff tears using a bioinductive implant show safety and efficacy at 1‐year follow‐up. Level of Evidence: Retrospective case series, level IV evidence.Keywords
This publication has 38 references indexed in Scilit:
- Histopathology of Residual Tendon in High‐Grade Articular‐Sided Partial‐Thickness Rotator Cuff Tears (PASTA Lesions)Arthroscopy, 2012
- A Prospective, Randomized Evaluation of Acellular Human Dermal Matrix Augmentation for Arthroscopic Rotator Cuff RepairArthroscopy, 2011
- Rotator Cuff Repair Healing Influenced by Platelet‐Rich Plasma Construct AugmentationArthroscopy, 2011
- The Arthroscopic Management of Partial‐Thickness Rotator Cuff Tears: A Systematic Review of the LiteratureArthroscopy, 2011
- Minimal clinically important differences (MCID) and patient acceptable symptomatic state (PASS) for visual analog scales (VAS) measuring pain in patients treated for rotator cuff diseaseJournal of Shoulder and Elbow Surgery, 2009
- Biomechanical analysis of bursal-sided partial thickness rotator cuff tearsJournal of Shoulder and Elbow Surgery, 2009
- Modulation of aggrecan and ADAMTS expression in ovine tendinopathy induced by altered strainArthritis & Rheumatism, 2008
- Intra-Articular Partial-Thickness Rotator Cuff TearsThe American Journal of Sports Medicine, 2007
- Stress distribution in the supraspinatus tendon with partial-thickness tears: An analysis using two-dimensional finite element modelJournal of Shoulder and Elbow Surgery, 2006
- The Joint Side Tear of the Rotator CuffClinical Orthopaedics and Related Research, 1994