A Bioinspired Flexible Film Fabricated by Surface-Tension-Assisted Replica Molding for Dynamic Control of Unidirectional Liquid Spreading
Authors:
- Zeming LiZLZeming Li
- Deyuan ZhangDZDeyuan Zhang
- Dongyue WangDWDongyue Wang
- Liwen ZhangLZLiwen Zhang
- Lin FengLin Feng
- Xiangyu ZhangXZXiangyu Zhang
- 2 December 2019
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (51) , 48505-48511
Abstract
The unidirectional liquid spreading without external energy input has presently aroused widespread concern. Recently, on the peristome of Nepenthes alata, a novel 2D unidirectional liquid spreading has been reported. It has been revealed that its exquisite superhydrophilic multistage microstructure, overlapping microcavities with arc-shaped edges and wedge-shaped corners, is the main reason for this phenomenon. To fabricate a peristome-inspired surface, a replica molding method is highly efficient and provides an ideal structure. However, the curved shape of the finally formed surface cannot be adjusted, and a specific surface shows only one type of liquid spreading state, greatly limiting its potential application. Here, we aimed to develop a novel surface tension-assisted replica molding method to fabricate an artificial peristome film. The artificial peristome film was fabricated by pouring styrenic block copolymers (SBS) dissolved in organic solvents into a negative replica prepared in polydimethylsiloxane (PDMS), based on the natural peristome. With volatilizing the organic solvent, the SBS agglomerates formed an artificial peristome film via surface tension effects. More importantly, the PDMS-negative replica swelled in the organic solvent, and then returned to the original size, which is conducive for replicating microstructures. The liquid spreading speed could be dynamically controlled by stretching the artificial peristome film. We demonstrated that the microcavity wedge angle decreases with an increasing stretching ratio. A smaller wedge angle can result in a much stronger unidirectional liquid spreading ability. This study provides insight into the dynamic control of unidirectional liquid spreading for novel pump-free medical microfluidic devices.Keywords
Funding Information
- Beihang University (YCSJ-03-2018-04)
- National Natural Science Foundation of China (51290292)
- China Defense Industrial Technology Development Program (JCKY2018601C209)
This publication has 35 references indexed in Scilit:
- A multi-structural and multi-functional integrated fog collection system in cactusNature Communications, 2012
- Electrical circuits from capillary flow driven evaporation deposition of carbon nanotube ink in non-porous V-groovesJournal of Colloid and Interface Science, 2011
- Capillary driven low-cost V-groove microfluidic device with high sample transport efficiencyLab on a Chip, 2010
- Uni-directional liquid spreading on asymmetric nanostructured surfacesNature Materials, 2010
- Directional water collection on wetted spider silkNature, 2010
- Surface Tension Transport of Prey by Feeding Shorebirds: The Capillary RatchetScience, 2008
- Mechanical and swelling properties of PDMS interpenetrating polymer networksPolymer, 2006
- The “Cheerios effect”American Journal of Physics, 2005
- Artificial Lotus Leaf by NanocastingLangmuir, 2005
- Effects of Casting Solvents on the Formation of Inverted Phase in Block Copolymer Thin FilmsMacromolecules, 2004