Purpose: The appearance of parenchymal/stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power‐law shape described by the exponential parameter,β. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences the texture and appearance of the patterns formed in a mammogram. Here, a large study is performed to investigate the variations in β in a clinical population and to indicate the relationship between β and breast density.Methods: From a set of 2686 cranio‐caudal normal screening mammograms, the parameterβ was extracted from log‐log fits to the Wiener spectrum over the range 0.15–1 mm−1. The Wiener spectrum was calculated from regions of interest in the compression paddle contact region of the breast. An in‐house computer program, Cumulus V, was used to extract the volumetric breast density and identify the compression paddle contact regions of the breast. The Wiener spectra were calculated with and without modulation transfer function (MTF) correction to determine the impact of VBD on the intrinsic anatomic noise.Results: The mean volumetric breast density was 25.5% (±12.6%) over all images. The meanβ following a MTF correction which decreased the β slightly (≈−0.08) was found to be 2.87. Varying the maximum of the spatial frequency range of the fits from 0.7 to 1.0, 1.25 or 1.5 mm−1 showing small decreases in the result, although the effect of the quantum noise power component on reducing β was clearly observed at 1.5 mm−1.Conclusions: The texture parameter,β, was found to increase with VBD at low volumetric breast densities with an apparent leveling off at higher densities. The relationship between β and VBD measured here can be used to create probabilistic models for computer simulations of detectability. As breast density is a known risk predictor for breast cancer, the correlation between β and VBD suggests that β may provide predictive information and this will be investigated in the future.Keywords
Funding Information
- Canadian Cancer Society Research Institute (2010-700538)
This publication has 16 references indexed in Scilit:
- Cascaded analysis of signal and noise propagation through a heterogeneous breast modelMedical Physics, 2010
- Validation of a method for measuring the volumetric breast density from digital mammogramsPhysics in Medicine & Biology, 2010
- The myth of the 50‐50 breastMedical Physics, 2009
- Comparison of power spectra for tomosynthesis projections and reconstructed imagesMedical Physics, 2009
- Accurate estimation of compressed breast thickness in mammographyMedical Physics, 2009
- Measurement of compressed breast thickness by optical stereoscopic photogrammetryMedical Physics, 2009
- Characterizing anatomical variability in breast CT imagesMedical Physics, 2008
- Breast Density and Parenchymal Patterns as Markers of Breast Cancer Risk: A Meta-analysisCancer Epidemiology, Biomarkers & Prevention, 2006
- Human observer detection experiments with mammograms and power‐law noiseMedical Physics, 2001
- Statistically defined backgrounds:performance of a modified nonprewhitening observer modelJournal of the Optical Society of America A, 1994