Enabling orders of magnitude sensitivity improvement for quantification of Ga in a Ce matrix with a compact Echelle spectrometer
- 14 September 2022
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (10) , 1975-1980
Abstract
Chemical analysis of lanthanide materials via laser-induced breakdown spectroscopy (LIBS) is often hindered by the complex spectral response and self-absorption phenomena that occur in the LIBS plasma. Previous attempts to quantify the alloying metal gallium in cerium matrices with a handheld LIBS analyzer were plagued by the inability to resolve major Ga atomic emissions and self-absorption effects, diminishing the fidelity of calibration curves. However, implementing a compact, high resolution Echelle spectrometer coupled with a Stark-broadening based self-absorption correction can enable proper recording of the main Ga I emission at 417.2 nm and improve the sensitivity of calibration curves by two orders of magnitude compared to the handheld device. We demonstrate this by using the mathematical correction on recorded high-resolution spectra from Ce–Ga samples to achieve calibration curves with detection limits as low as 0.008 wt% Ga. This study indicates that using a compact spectrometer capable of higher resolution measurements can yield higher fidelity solutions for Pu chemical analysis via LIBS in constrained environments, e.g., in a glovebox – enabling higher sensitivity in rapid detection of minor elements.Keywords
Funding Information
- Air Force Office of Scientific Research
- Defense Threat Reduction Agency
This publication has 39 references indexed in Scilit:
- Algorithm 916ACM Transactions on Mathematical Software, 2011
- High-fluence femtosecond laser ablation of silica glass: effects of laser-induced pressureJournal of Physics D: Applied Physics, 2011
- Laser-Induced Breakdown Spectroscopy (LIBS), Part I: Review of Basic Diagnostics and Plasma—Particle Interactions: Still-Challenging Issues within the Analytical Plasma CommunityApplied Spectroscopy, 2010
- Towards the determination of the geographical origin of yellow cake samples by laser-induced breakdown spectroscopy and chemometricsJournal of Analytical Atomic Spectrometry, 2009
- Multivariate analysis of remote laser-induced breakdown spectroscopy spectra using partial least squares, principal component analysis, and related techniquesSpectrochimica Acta Part B: Atomic Spectroscopy, 2009
- Artificial neural network for Cu quantitative determination in soil using a portable Laser Induced Breakdown Spectroscopy systemSpectrochimica Acta Part B: Atomic Spectroscopy, 2008
- Evaluation of self-absorption coefficients of aluminum emission lines in laser-induced breakdown spectroscopy measurementsSpectrochimica Acta Part B: Atomic Spectroscopy, 2005
- Investigation of Selected Baseline Removal Techniques as Candidates for Automated ImplementationApplied Spectroscopy, 2005
- Correction of the self-absorption for reversed spectral lines: application to two resonance lines of neutral aluminiumJournal of Quantitative Spectroscopy and Radiative Transfer, 2003
- Self-Absorption of Spectrum LinesReviews of Modern Physics, 1948