Is There Evidence for Continued Learning Over Multiple Years in Perimetry?
- 1 November 2008
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 85 (11) , 1043-1048
Abstract
Purpose.: The existence of learning effects in perimetry, whereby a subject's first test is more variable and has lower mean sensitivity (MS) than subsequent tests, is well established. However, studies have typically examined this issue by testing subjects at a frequency that would be unusual in a clinical setting. This study seeks to determine the validity of these conclusions for less frequent, yet more clinically realistic, testing rates. Methods.: One hundred sixty eyes of 80 subjects with suspected or early glaucoma were included. Subjects were tested annually for 8 years using white‐on‐white standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP). All subjects had undergone at least one test with both paradigms before entering the study. Results.: For SAP, MS increased by 0.5 dB over the first year, and then showed no significant change until after year 5 (despite expected effects of aging and disease progression), after which it started to decline. For SWAP, MS of the average eye continued to improve until year 6 of the study. Conclusions.: Our findings seem to indicate a prolonged learning effect for SWAP, with MS increasing for several years. A smaller prolonged learning effect may also be present for SAP, counteracting the effects of aging and disease progression. Deterioration of the subject's visual field may be underestimated within this period.Keywords
Funding Information
- National Eye Institute
This publication has 25 references indexed in Scilit:
- Quantifying Adaptation and Fatigue Effects in Frequency Doubling PerimetryInvestigative Ophthalmology & Visual Science, 2007
- Normal Age‐Related Sensitivity Loss for a Variety of Visual Functions Throughout the Visual FieldOptometry and Vision Science, 2006
- Modeling the sensitivity to variability relationship in perimetryVision Research, 2006
- Evidence for a Learning Effect in Short-Wavelength Automated PerimetryOphthalmology, 2006
- Visual Field Progression in Glaucoma: Total Versus Pattern Deviation AnalysesInvestigative Ophthalmology & Visual Science, 2005
- Evaluation of the Structure-Function Relationship in GlaucomaInvestigative Ophthalmology & Visual Science, 2005
- Characteristics of the Normative Database for the Humphrey Matrix PerimeterInvestigative Ophthalmology & Visual Science, 2005
- The influence of the learning effect on automated perimetry in patients with suspected glaucomaActa Ophthalmologica, 1989
- The Effect of Perimetric Experience in Normal SubjectsArchives of Ophthalmology (1950), 1989
- Longitudinal data analysis using generalized linear modelsBiometrika, 1986