Abstract
To review the design and function of pacemakers and implantable cardioverter defibrillators with particular attention to those aspects that are of clinical relevance to perioperative and critical care physicians. Pacemakers and implantable cardioverter defibrillators are complex devices that interact with cardiac function in ways that can significantly influence hemodynamics. A basic appreciation of device technology is essential to understanding both the normal patterns of pacemaker and implantable cardioverter defibrillator usage and the ways in which iatrogenic influences may result in adverse outcomes. The most important concern for pacemaker patients who enter the hospital is exposure to electromagnetic interference. Exposure is mainly from surgical cautery, but other sources are also present. With awareness of these concerns and an understanding of how to prevent adverse interactions, it is possible to safely care for these patients in the critical care setting. Despite recommended precautions, undesirable outcomes may occur and the clinician must be prepared to intervene in an appropriate manner to prevent patient injury.Keywords
This publication has 30 references indexed in Scilit:
- ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Summary ArticleCirculation, 2002
- Cardiac Rhythm Management Devices (Part II)Anesthesiology, 2001
- Intraoperative Pacemaker Malfunction during a Shoulder ArthroscopyAnesthesiology, 2000
- Inappropriate Rate Change in Minute Ventilation Rate Responsive Pacemakers Due to Interference by Cardiac MonitorsPacing and Clinical Electrophysiology, 1997
- Lithium/Carbon Monofluoride (Li/CFx): A New Pacemaker BatteryPacing and Clinical Electrophysiology, 1996
- Safe Performance of Magnetic Resonance Imaging on Five Patients with Permanent Cardiac PacemakersPacing and Clinical Electrophysiology, 1996
- Do Steroid‐Eluting Electrodes Really Have Better Performance Than Other State‐of‐the‐Art Designs?Pacing and Clinical Electrophysiology, 1993
- Intraoperative Pacemaker-mediated TachycardiaAnesthesiology, 1993
- Rate Responsive Pacing and Exercise Capacity‐A CommentPacing and Clinical Electrophysiology, 1989
- Termination of Malignant Ventricular Arrhythmias with an Implanted Automatic Defibrillator in Human BeingsNew England Journal of Medicine, 1980