Optical Coherence Tomography—Enhanced Microlaryngoscopy: Preliminary Report of a Noncontact Optical Coherence Tomography System Integrated with a Surgical Microscope
Authors:
- Ryan JacksonRJRyan Jackson
- Shuguang GuoSGShuguang Guo
- Jorge A. PerezJPJorge A. Perez
- Jianping SuJSJianping Su
- James M. RidgwayJRJames M. Ridgway
- William B. ArmstrongWAWilliam B. Armstrong
- Zhongping ChenZhongping Chen
- Brian J. F. WongBWBrian J. F. Wong
Open Access
- 1 July 2008
- journal article
- research article
- Published by SAGE Publications in Annals of Otology, Rhinology & Laryngology
- Vol. 117 (7) , 538-547
Abstract
Objectives: Optical coherence tomography (OCT) is a new imaging modality that uses near-infrared light to produce cross-sectional images of tissue with a resolution approaching that of light microscopy. We have previously reported use of OCT imaging of the vocal folds (VFs) during direct laryngoscopy with a probe held in contact or near-contact with the VFs. This aim of this study was to develop and evaluate a novel OCT system integrated with a surgical microscope to allow hands-free OCT imaging of the VFs, which could be performed simultaneously with microscopic visualization. Methods: We performed a prospective evaluation of a new method of acquiring OCT images of the VFs. Results: An OCT system was successfully integrated with a surgical microscope to permit noncontact OCT imaging of the VFs of 10 patients. With this novel device we were able to identify VF epithelium and lamina propria; however, the resolution was reduced compared to that achieved with the standard contact or near-contact OCT. Conclusions: Optical coherence tomography is able to produce high-resolution images of vocal fold mucosa to a maximum depth of 1.6 mm. It may be used in the diagnosis of VF lesions, particularly early squamous cell carcinoma, in which OCT can show disruption of the basement membrane. Mounting the OCT device directly onto the operating microscope allows hands-free noncontact OCT imaging and simultaneous conventional microscopic visualization of the VFs. However, the lateral resolution of the OCT microscope system is 50 μm, in contrast to the conventional handheld probe system (10 μm). Although such images at this resolution are still useful clinically, improved resolution would enhance the system's performance, potentially enabling real-time OCT-guided microsurgery of the larynx.Keywords
This publication has 22 references indexed in Scilit:
- Optical coherence tomography of the newborn airway.2008
- Imaging of the Pediatric Airway Using Optical Coherence TomographyThe Laryngoscope, 2007
- Optical Coherence Tomography of Laryngeal CancerThe Laryngoscope, 2006
- Imaging the Human Vocal Folds in Vivo with Optical Coherence Tomography: A Preliminary ExperienceAnnals of Otology, Rhinology & Laryngology, 2006
- In Vivo Optical Coherence Tomography of the Nasal MucosaAmerican Journal of Rhinology, 2006
- In Vivo Optical Coherence Tomography of the Human Larynx: Normative and Benign Pathology in 82 PatientsThe Laryngoscope, 2005
- Two-dimensional and 3-dimensional optical coherence tomographic imaging of the airway, lung, and pleuraThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Optical coherence tomography for ultrahigh resolution in vivo imagingNature Biotechnology, 2003
- Phase-resolved functional optical coherence tomography: simultaneous imaging of in situ tissue structure, blood flow velocity, standard deviation, birefringence, and Stokes vectors in human skinOptics Letters, 2002
- Optical Coherence TomographyScience, 1991