Total hip arthroplasty for rheumatoid arthritis in younger patients: 2,557 replacements in the Finnish Arthroplasty Register followed for 0–24 years
Authors:
Open Access
- 1 January 2006
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 77 (6) , 853-865
Abstract
Background The results of total hip arthroplasty (THA) in young patients with rheumatoid arthritis (RA) have been reported in only a few studies. On a nationwide level, the outcome of THA in these patients is unknown. We evaluated the population-based survival of THA in patients under 55 years of age with RA and factors affecting the survival. Patients Between 1980 and 2003, 2,557 primary THAs performed for RA in patients less than 55 years of age were reported to the Finnish Arthroplasty Register. Results Proximally circumferentially porous-coated uncemented stems had a 15-year survival rate of 89% (95% CI 83–94) with aseptic loosening as endpoint. The risk of stem revision due to aseptic loosening was higher with cemented stems than with proximally porouscoated uncemented stems implanted during the same period (RR 2.4; p < 0.001). In contrast, Cox regression analysis showed that the risk of cup revision was significantly higher for all uncemented cup concepts than for all-polyethylene cemented cups with any cup revision as endpoint. There were no significant differences in survival between the THR concepts. Interpretations Uncemented proximally circumferentially porous-coated stems and cemented all-poly-ethylene cups are currently the implants of choice for young patients with RA.Keywords
This publication has 34 references indexed in Scilit:
- Uncemented total hip arthroplasty for primary osteoarthritis in young patients: A mid-to long-term follow-up study from the Finnish Arthroplasty RegisterActa Orthopaedica, 2006
- Total hip arthroplasty for primary osteoarthrosis in younger patients in the Finnish arthroplasty registerActa Orthopaedica, 2005
- Catastrophic failure of an uncemented acetabular component due to high wear and osteolysisAn analysis of 154 Omnifit prostheses with mean 6-year follow-upActa Orthopaedica, 2004
- High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses65 hips in 56 young patients followed for 5–9 yearsActa Orthopaedica, 2004
- Cementless acetabular replacement in patients with rheumatoid arthritisA 6- to 14-year prospective studyThe Journal of Arthroplasty, 2003
- Alarming wear of the first-generation polyethylene liner of the cementless porous-coated Biomet Universal cup: 107 hips followed for mean 6 yearsActa Orthopaedica, 2001
- The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplastiesActa Orthopaedica, 2000
- Middle-Term Results of Threaded Acetabular Cups: High Failure Fates Five Years After SurgeryThe Journal of Bone and Joint Surgery. British volume, 1997
- Periarticular bone in rheumatoid arthritis versus arthrosis: Histomorphometry in 103 hip biopsiesActa Orthopaedica, 1994
- Registration of arthroplasties in FinlandActa Orthopaedica, 1991