Abstract
In our laboratory, we study different factors that influence the microemboli counts in the extracorporeal circuit using a simulated pediatric cardiopulmonary bypass (CPB) model identical to the one used in our operating rooms. For monitoring and classification of microemboli, we use the novel Emboli Detection and Classification (EDAC) Quantifier system which allows for real-time monitoring, localization, and size characterization of microemboli as small as 10 μm. Our results show that high flow rates, low perfusate temperature, use of vacuum assisted venous drainage (VAVD), use of roller pump, and pulsatile flow results in higher microemboli counts at postpump site. Microemboli counts at postoxygenator, and postfilter sites are significantly less. This indicates that hollow fiber membrane oxygenator was able to remove most of the microemboli, and an opened arterial filter purge line augments the removal of microemboli that were not captured by the oxygenator. Majority of the microemboli detected at all sites were <40 μm in size. Based on the results of our studies, we started using the EDAC Quantifier system in our operating rooms at Penn State Hershey Children’s Hospital. More basic science studies and clinical outcome data are needed for further study in minimizing the adverse effects of pediatric CPB procedure.Keywords
This publication has 23 references indexed in Scilit:
- “Stolen” Blood Flow: Effect of an Open Arterial Filter Purge Line in a Simulated Neonatal CPB ModelASAIO Journal, 2008
- Delivery of Gaseous Microemboli With Vacuum-Assisted Venous Drainage During Pulsatile and Nonpulsatile Perfusion in a Simulated Neonatal Cardiopulmonary Bypass ModelASAIO Journal, 2008
- Microemboli Detection and Classification by Innovative Ultrasound Technology During Simulated Neonatal Cardiopulmonary Bypass at Different Flow Rates, Perfusion Modes, and Perfusate TemperaturesASAIO Journal, 2008
- Assessment of Hydraulic Performance and Biocompatibility of a MagLev Centrifugal Pump System Designed for Pediatric Cardiac or Cardiopulmonary SupportASAIO Journal, 2007
- Pulsatile Perfusion During Cardiopulmonary Bypass Procedures in Neonates, Infants, and Small ChildrenASAIO Journal, 2007
- Detection and Classification of Gaseous Microemboli During Pulsatile and Nonpulsatile Perfusion in a Simulated Neonatal CPB ModelASAIO Journal, 2007
- Quantification of Perfusion Modes in Terms of Surplus Hemodynamic Energy Levels in a Simulated Pediatric CPB ModelASAIO Journal, 2006
- An Evaluation of the Benefits of Pulsatile versus Nonpulsatile Perfusion during Cardiopulmonary Bypass Procedures in Pediatric and Adult Cardiac PatientsASAIO Journal, 2006
- Outcomes of the First International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary PerfusionASAIO Journal, 2006
- Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass?The Annals of Thoracic Surgery, 2002