Abstract
Dynamic analyses were carried out to study the seismic response of high‐rise steel moment‐resisting frames in 16‐storey buildings. The frames are intentionally designed using three different design procedures: strength‐controlled design, strong column–weak beam controlled design, and drift‐controlled design. The seismic performances of the so‐designed frames with vertical mass irregularities were discussed in view of drift ratio, plastic hinge rotation, hysteretic energy input and stress demand. A demand curve of hysteretic energy inputs was also presented with two earthquake levels in peak ground accelerations for a future design application. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 8 references indexed in Scilit:
- Empirical hysteretic energy with strength, strength and drift, and SCWB designs using steel moment-resisting framesThe Structural Design of Tall Buildings, 2001
- 7. Seismic Response of an Instrumented 13‐Story Steel Frame Building Damaged in the 1994 Northridge EarthquakeEarthquake Spectra, 1997
- Seismic Response of Building Frames with Vertical Structural IrregularitiesJournal of Structural Engineering, 1997
- Seismic‐Energy Dissipation in MDOF StructuresJournal of Structural Engineering, 1992
- Evaluation of seismic energy in structuresEarthquake Engineering & Structural Dynamics, 1990
- Earthquake Load for Structural ReliabilityJournal of Structural Engineering, 1989
- Earthquake Energy Absorption in SDOF StructuresJournal of Structural Engineering, 1984