Analysis of perfusion MRI in stroke: To deconvolve, or not to deconvolve
- 31 October 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (4) , 1282-1290
Abstract
Purpose: There is currently controversy regarding the benefits of deconvolution‐based parameters in stroke imaging, with studies suggesting a similar infarct prediction using summary parameters. We investigate here the performance of deconvolution‐based parameters and summary parameters for dynamic‐susceptibility contrast (DSC) MRI analysis, with particular emphasis on precision.Methods: Numerical simulations were used to assess the contribution of noise and arterial input function (AIF) variability to measurement precision. A realistic AIF range was defined based on in vivo data from an acute stroke clinical study. The simulated tissue curves were analyzed using two popular singular value decomposition (SVD) based algorithms, as well as using summary parameters.Results: SVD‐based deconvolution methods were found to considerably reduce the AIF‐dependency, but a residual AIF bias remained on the calculated parameters. Summary parameters, in turn, show a lower sensitivity to noise. The residual AIF‐dependency for deconvolution methods and the large AIF‐sensitivity of summary parameters was greatly reduced when normalizing them relative to normal tissue.Conclusion: Consistent with recent studies suggesting high performance of summary parameters in infarct prediction, our results suggest that DSC‐MRI analysis using properly normalized summary parameters may have advantages in terms of lower noise and AIF‐sensitivity as compared to commonly used deconvolution methods. Magn Reson Med 76:1282–1290, 2016.Keywords
This publication has 48 references indexed in Scilit:
- The 39 steps: evading error and deciphering the secrets for accurate dynamic susceptibility contrast MRINMR in Biomedicine, 2012
- The Role of Bolus Delay and Dispersion in Predictor Models for StrokeStroke, 2012
- Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilitiesMagnetic Resonance Materials in Physics, Biology and Medicine, 2009
- Comparison of 10 Perfusion MRI Parameters in 97 Sub-6-Hour Stroke Patients Using Voxel-Based Receiver Operating Characteristics AnalysisStroke, 2009
- Identification of Penumbra and Infarct in Acute Ischemic Stroke Using Computed Tomography Perfusion–Derived Blood Flow and Blood Volume MeasurementsStroke, 2006
- Refining the Perfusion–Diffusion Mismatch HypothesisStroke, 2005
- Cerebral Blood Flow and Cerebrovascular Reserve Capacity: Estimation by Dynamic Magnetic Resonance ImagingJournal of Cerebral Blood Flow & Metabolism, 1998
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Mr imaging of cerebral perfusion by phase‐angle reconstruction of bolus paramagnetic‐induced frequency shiftsMagnetic Resonance in Medicine, 1992
- A simplified formulation of the gamma variate functionPhysics in Medicine & Biology, 1992