Estimation of Carrier Suppression by High-Energy Boron-Implanted Layer for Soft Error Reduction

Authors:
  • TKTakehisa Kishimoto
    Takehisa Kishimoto
  • HSHirokazu Sayama
    Hirokazu Sayama
  • MTMikio Takai
    Mikio Takai
  • YOYoshikazu Ohno
    Yoshikazu Ohno
  • KSKenichirou Sonoda
    Kenichirou Sonoda
  • TNTadashi Nishimura
    Tadashi Nishimura
  • AKAtsushi Kinomura
    Atsushi Kinomura
  • YHYuji Horino
    Yuji Horino
  • KFKanenaga Fujii
    Kanenaga Fujii

Abstract
Effect of charge-carrier suppression by a high-energy boron-implanted layer has been investigated by ion-induced-current measurement using high-energy proton microprobes. Proton microprobes at 1.3 and 2.0 MeV have been irradiated normal to the n+p diode to generate electron-hole pairs. The collection of charge carriers induced by microprobe irradiation could be reduced by a buried layer formed by boron implantation. It was found that the rate of charge collection depended on the implantation dose but not on the depth of the buried layer.