On‐site adequacy evaluations performed by cytotechnologists
Authors:
- 31 August 2011
- journal article
- research article
- Published by Wiley in Cancer Cytopathology
- Vol. 120 (3) , 177-184
Abstract
BACKGROUND: Practice patterns regarding on‐site assessment of the adequacy of image‐guided fine‐needle aspiration biopsies (FNABs) vary among laboratories, but in many laboratories primary responsibility rests with the cytotechnologists. On‐site evaluation provides feedback on the need for additional passes and facilitates triaging of the specimen for time‐sensitive ancillary studies. Prior studies have suggested that cytotechnologists can assess the initially obtained specimens correctly, but they are few in number and limited by small size. The purpose of this study was to assess the frequency with which our cytotechnologists were able to correctly assess specimens as adequate using a large‐scale database that included a wide range of image‐guided FNABs.METHODS: The frequency that on‐site adequacy assessments of 5241 image‐guided FNABs were correct was determined by correlating the cytotechnologists' assessments of adequacy with the final cytologic interpretation. An adequacy assessment was considered correct if the FNAB was ultimately reported as satisfactory and unequivocally benign or malignant. An adequate reading on a case that was ultimately reported as unsatisfactory, atypical, or suspicious was deemed “incorrect.” The effect of imaging modality was also analyzed.RESULTS: Of 5241 FNABs, 2784 (53%) were interpreted as adequate on site. Of these, 2637 (95%) were correctly considered adequate. Of the common biopsy sites sampled, the adequacy assessments for liver FNABs demonstrated the highest frequency for being correctly considered adequate (97%) and those for kidney FNABs showed the lowest (90%). Imaging modality had no effect on accuracy.CONCLUSIONS: Cytotechnologists are almost always correct when assessing initial FNAB samples as adequate. Cancer (Cancer Cytopathol) 2012;. © 2011 American Cancer Society.Keywords
This publication has 30 references indexed in Scilit:
- Effect of Advanced Imaging Technology on How Biopsies Are Done and Who Does ThemRadiology, 2010
- Cytology of endobronchial ultrasound‐guided transbronchial needle aspirationCancer Cytopathology, 2009
- Aetiology of non‐diagnostic renal fine‐needle aspiration cytologies in a contemporary seriesBJU International, 2008
- Number of Needle Passes Does Not Correlate with the Diagnostic Yield of Renal Fine Needle Aspiration CytologyJournal of Endourology, 2008
- Specimen adequacy and diagnostic specificity of ultrasound-guided fine needle aspirations of nonpalpable thyroid nodulesDiagnostic Cytopathology, 2006
- The Impact of Assessing Specimen Adequacy and Number of Needle Passes for Fine-Needle Aspiration Biopsy of Thyroid NodulesThyroid®, 2006
- Ultrasound-Guided Fine-Needle Capillary Biopsy of Thyroid Nodules, Coupled with On-Site Cytologic Review, Improves ResultsThyroid®, 2004
- Cost-Effectiveness of Immediate Specimen Adequacy Assessment of Thyroid Fine-Needle AspirationsAmerican Journal of Clinical Pathology, 2004
- Diagnostic value and cost‐effectiveness of on‐site evaluation of fine‐needle aspiration specimens: Review of 5,688 casesDiagnostic Cytopathology, 2002
- Immediate on-site interpretation of fine-needle aspiration smearsCancer, 2001