Preoperative assessment of bone density for dental implantation: a comparative study of three different ROI methods
Open Access
- 18 May 2024
- journal article
- research article
- Published by Springer Nature in Head & Face Medicine
- Vol. 20 (1) , 1-11
Abstract
Dental cone beam computed tomography (CBCT) is commonly used to evaluate cancellous bone density before dental implant surgery. However, to our knowledge, no measurement approach has been standardized yet. This study aimed to evaluate the relationship between three different regions of interest (ROI) methods on cancellous bone density at the dental implant site using dental CBCT images. Patients’ dental CBCT images (n = 300) obtained before dental implant surgery were processed using Mimics (Materialise, Leuven, Belgium). At the potential implant sites, the rectangle, cylinder, and surrounding cylinder ROI methods were used to measure bone density. Repeated measures one-way analysis of variance was performed to compare the three ROI methods in terms of measurement results. Pearson correlation analysis was performed to identify the likely pair-wise correlations between the three ROI methods. The density value obtained using the surrounding cylinder approach (grayscale value [GV],523.56 ± 228.03) was significantly higher than the values obtained using the rectangle (GV, 497.04 ± 236.69) and cylinder (GV,493 ± 231.19) ROI methods in terms of results. Furthermore, significant correlations were noted between the ROI methods (r > 0.965; p < 0.001). The density measured using the surrounding cylinder method was the highest. The choice of method may not influence the trends of measurement results. This study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH111-REC3-205. Informed consent was waived by the Institutional Review Board of China Medical University Hospital, CMUH111-REC3-205, owing to the retrospective nature of the study.Keywords
Funding Information
- China Medical University, Taiwan (CMU111-MF-92)
This publication has 40 references indexed in Scilit:
- Insertion Speed Affects the Initial Stability of Dental ImplantsJournal of Medical and Biological Engineering, 2022
- Biomechanical Analysis of Mandibular Implant-Assisted Removable Partial Denture with Distal ExtensionJournal of Medical and Biological Engineering, 2022
- Biomechanical Effects of Bone Atrophy, Implant Design, and Vertical or Tilted of Posterior Implant on All-on-Four Concept Implantation: Finite Element AnalysisJournal of Medical and Biological Engineering, 2022
- Primary Stability of Conventionally Tapered Versus Reverse Tapered Body Shift Implants Under Varying Bone Support Conditions—An In-Vitro StudyJournal of Medical and Biological Engineering, 2022
- Stress Distribution of Four-Unit Implant-Supported Fixed Partial Prosthesis with Different Numbers and Positions of Fixtures in Maxilla Anterior Region-3D FEAJournal of Medical and Biological Engineering, 2022
- Relation between initial implant stability quotient and bone-implant contact percentage: an in vitro model studyOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2013
- Effects of the 3D bone-to-implant contact and bone stiffness on the initial stability of a dental implant: micro-CT and resonance frequency analysesInternational Journal of Oral and Maxillofacial Surgery, 2013
- A systematic review of prosthetic restoration in patients with shortened dental archesJapanese Dental Science Review, 2011
- In vivo measurement of mandibular bone mineral density in normal dental subjects by dual-energy x-ray absorptiometry (DEXA).Bone, 1996
- Implant survival rates in partially edentulous patientsJournal of Oral and Maxillofacial Surgery, 1995