Monitoring interface traps by DCIV method
Authors:
- Chih-Tang SahCSChih-Tang Sah
- 1 January 1999
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 20 (1) , 60-63
Abstract
DCIV method is demonstrated as a production monitoring tool for process-residue interface traps. The high sensitivity of the methodology attained from forward-biasing a p-n junction allows routine detection of as few as 100 active interface traps in small area MOS transistors. Examples are given for MOST's from five different sub-half-micron production technologies. The body recombination current shows peaks around the intrinsic surface condition whose amplitude is proportional to the number of active interface traps in the mid-channel region. The variation of the peak amplitude with the forward bias voltage follows exactly the single-energy level formula, from which the interface-trap energy level can be determined to a few tenths of a kT accuracy.Keywords
This publication has 7 references indexed in Scilit:
- Evidence of discrete interface traps on thermally grown thin silicon oxide filmsApplied Physics Letters, 1999
- Profiling interface traps in MOS transistors by the DC current-voltage methodIEEE Electron Device Letters, 1996
- Direct-current measurements of oxide and interface traps on oxidized siliconIEEE Transactions on Electron Devices, 1995
- A reliable approach to charge-pumping measurements in MOS transistorsIEEE Transactions on Electron Devices, 1984
- Error analysis of surface state density determination using the MOS capacitance methodSolid-State Electronics, 1969
- The Si-SiO2Interface - Electrical Properties as Determined by the Metal-Insulator-Silicon Conductance TechniqueBell System Technical Journal, 1967
- An investigation of surface states at a silicon/silicon oxide interface employing metal-oxide-silicon diodesSolid-State Electronics, 1962