A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients
Open Access
- 4 September 2020
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-8
Abstract
Background: Aseptic cup loosening is still one of the main reasons leading to acetabular cup failures. 3D printing porous trabecular titanium metal acetabular cup may provide good initial stability and secondary fixation because of its highly interconnected, porous structure. Few large sample studies have reported the clinical outcomes of electron beam melting (EBM) porous titanium acetabular cup in Chinese population.Methods: We retrospectively collected and analyzed the clinical data of a total of 92 consecutive patients between January 2013 and November 2017, with an average follow-up of 48.2 ± 3.6 months. Clinical outcomes included Harris Hip Score (HHS), the Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index, satisfaction rate, and cup survival rate were evaluated. Radiographic assessments were conducted to evaluate osteointegration.Results: HHS scores improved significantly while the WOMAC score decreased significantly at the latest follow-up (p< 0.001). The satisfaction rate (prevalence of satisfied or very satisfied) was 91.3%. No acetabular cup failures occurred. Radiolucent lines appeared in 15 cases (18 hips) and disappeared in 6 months. No cup loosening signs found until the last follow-up. The overall survival rate of implantation is 99.1% (cup survival rate 100%).Conclusion: The new EBM-produced 3D ACT™ cup demonstrated us its favorable short- to mid-term clinical outcomes in Chinese THA patients. It can provide high acetabular cup survival rate, great clinical improvements and excellent biological fixation. Further investigations are needed to confirm its long-term outcomes.Keywords
All Related Versions
This publication has 30 references indexed in Scilit:
- A Randomized Trial Comparing Acetabular Component Fixation of Two Porous Ingrowth Surfaces Using RSAThe Journal of Arthroplasty, 2013
- What’s New in Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2012
- Comparative Survival of Uncemented Acetabular Components Following Primary Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2011
- Characterization of cellular solids in Ti6Al4V for orthopaedic implant applications: Trabecular titaniumJournal of the Mechanical Behavior of Biomedical Materials, 2010
- Fabrication and characterization of porous Ti6Al4V parts for biomedical applications using electron beam melting processMaterials Letters, 2009
- Cellular Ti–6Al–4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam meltingActa Biomaterialia, 2008
- Effects of topographical surface modifications of electron beam melted Ti‐6Al‐4V titanium on human fetal osteoblastsJournal of Biomedical Materials Research Part A, 2007
- Radiographic Signs of Osseointegration in Porous-coated Acetabular ComponentsClinical Orthopaedics and Related Research, 2006
- Long-Term Results Using the Anatomic Medullary Locking Hip ProsthesisClinical Orthopaedics and Related Research, 2001
- 10-Jahresergebnisse mit dem korundgestrahlten Reintitanschraubring nach ZweymüllerZeitschrift für Orthopädie und ihre Grenzgebiete, 1998