Health Assessment at Local Level with Unknown Input Excitation

Authors:

Abstract
A finite-element-based procedure is proposed to identify defects in existing structures and evaluate their extent at the local element level for the purpose of health assessment. The procedure is a time-domain system identification technique where input excitation is not required to identify a structure. It estimates the dynamic properties of a structure in terms of stiffness and damping at the element level in a finite-element representation. The method can be used to precisely locate a defective spot in an element. Although input excitation information is not required, examples are used to show that the algorithm is robust enough to identify a structure excited by different types of loading. Structures can be excited simultaneously by multiple loadings, and the response information can be noise-free or noise-contaminated. Defects can be small or relatively large. In all cases, the algorithm identified the structures correctly. The error in the identification is considerably smaller than that of other av...

This publication has 8 references indexed in Scilit: