Guide to simulating complex NMR probe circuits
Open Access
- 29 March 2018
- journal article
- research article
- Published by Wiley in Concepts in Magnetic Resonance Part A
- Vol. 47A (2)
Abstract
S‐parameter‐based circuit simulators are well suited to obtaining accurate solutions of even the most complex rf probe circuits. The basic theory necessary for determining the relative S/N of the probe circuit, based on B1/P0.5, from the voltage, current, impedance, and S‐parameter data that come from circuit simulators, is presented. Examples of simulator applications to circuits of increasing complexity are presented. A key requirement for effective utilization of circuit simulators in probe circuit optimizations is constructing an approximate analytical solution of the circuit, or an inverse simulation program, to accompany the direct circuit simulation, that calculates all the needed circuit component values based on minimal input data, such as B0, desired nuclides, sample coil description, and hardware options and details such as characteristics of various leads. A method of developing the needed inverse simulation program is presented for a simplified single‐coil HXY probe circuit. The inverse program is validated by the direct simulation itself. The methods are then applied to a detailed circuit that includes all significant leads, stray capacitances, couplings, and losses for a NB 28.2‐T 1‐mm HXYZ MAS probe. Similar HXY circuit models were validated by NMR experiments with rotor sizes from 0.75 mm to 3.2 mm at fields from 11.7 T to 21 T. Detailed HXYZ circuit model results at 11.7 T, including pulse widths, component values, voltages, and port isolations, agreed with experimental results within a few per cent. The 1200‐MHz HXYZ simulation predicted a 1H π/2 pulse of 1.3 μs at 25 W.Keywords
Funding Information
- National Institutes of Health (2R44 GM117905‐02)
This publication has 29 references indexed in Scilit:
- Design of a triple resonance magic angle sample spinning probe for high field solid state nuclear magnetic resonanceReview of Scientific Instruments, 2003
- Dissipation, resistance, and rational impedance matching for TEM and birdcage resonatorsConcepts in Magnetic Resonance, 2002
- NMR probeheads forin vivo applicationsConcepts in Magnetic Resonance, 2000
- Interplay among recovery time, signal, and noise: Series- and parallel-tuned circuits are not always the sameConcepts in Magnetic Resonance, 2000
- Practical Aspects of Birdcage CoilsJournal of Magnetic Resonance, 1999
- Resonant Modes of the Birdcage CoilJournal of Magnetic Resonance, 1997
- A multinuclear double-tuned probe for applications with solids or liquids utilizing lumped tuning elementsJournal of Magnetic Resonance (1969), 1981
- The NMR receiver: A description and analysis of designProgress in Nuclear Magnetic Resonance Spectroscopy, 1978
- Slotted tube resonator: A new NMR probe head at high observing frequenciesReview of Scientific Instruments, 1977
- Pulsed Nuclear Resonance ApparatusReview of Scientific Instruments, 1964