Results of Palmar Plating of the Lunate Facet Combined With External Fixation for the Treatment of High-Energy Compression Fractures of the Distal Radius
Authors:
- Charlie YangCYCharlie Yang
- Beth Paterson SmithBSBeth Paterson Smith
- 1 January 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 18 (1) , 28-33
Abstract
The study evaluated the outcome of the treatment of patients who sustained high-energy, compression-type injuries of the distal radius. The retrospective study evaluated the outcome of reduction and plating of the lunate facet in conjunction with standard external fixation. A Level I trauma center. Inclusion criteria for study participation included: 1) age between 18 and 65 years of age with no evidence of concomitant metabolic bone disease; and 2) a 3- or 4-part compression type fracture of the distal radius with residual displacement of the palmar lunate facet despite reduction of the dorsal cortex by the application of an external fixator. Fractures were treated with palmar plating of the depressed lunate facet combined with dorsal external fixation. Posttreatment evaluations consisted of measurements of range of motion, grip strength, radiographic evaluations, and completion of Disability of Arm, Shoulder, and Hand questionnaires. Three months after surgery, 20 of 21 patients exhibited full range of motion at the MCP/PIP joints. At the 2-year follow-up, an average palmar tilt of +1.0°, radial inclination of 24°, radial length of 12 mm, ulnar variance of 0.5 mm, intra-articular gap of 0.1 mm, and intra-articular step-off of 0.3 mm was documented. Using the Garland and Werley rating system, results were rated as excellent or good for 18 wrists, fair for 2 wrists, and poor for 1 wrist. Mean Disability of Arm, Shoulder, and Hand functional scores and athletic scores improved at 6 months. Reduction and plating of the lunate facet in conjunction with standard external fixation permits: 1) visualization and reduction of the palmar lunate facet; and 2) reduction of palmar tilt to neutral tilt without significant radial shortening. This technique should be considered as an acceptable option in the treatment of high-energy fractures of the distal radius.Keywords
This publication has 28 references indexed in Scilit:
- Development of an upper extremity outcome measure: The DASH (disabilities of the arm, shoulder, and head)American Journal of Industrial Medicine, 1996
- Results of combined internal and external fixation for the treatment of severe AO-C3 fractures of the distal radiusThe Journal of Hand Surgery, 1995
- Factors affecting functional outcome of displaced intra-articular distal radius fracturesThe Journal of Hand Surgery, 1994
- Severe fractures of the distal radius: Effect of amount and duration of external fixator distraction on outcomeThe Journal of Hand Surgery, 1993
- Open reduction and internal fixation for distal radius fracturesThe Journal of Hand Surgery, 1992
- Fractures of the distal end of the radius.Journal of Bone and Joint Surgery, 1991
- Intraarticular fractures of the distal radius: A cadaveric study to determine if ligamentotaxis restores radiopalmar tiltThe Journal of Hand Surgery, 1990
- Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radiusThe Journal of Hand Surgery, 1990
- Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bonesJournal of Bone and Joint Surgery, 1976
- EVALUATION OF HEALED COLLESʼ FRACTURESJournal of Bone and Joint Surgery, 1951