Detection of Clenbuterol at Trace Levels in Doping Analysis Using Different Gas Chromatographic–Mass Spectrometric Techniques

Authors:

Abstract
This study demonstrates the development of a gas chromatography–triple quadrupole tandem mass spectrometry (GC–MS-MS) assay to detect clenbuterol in human urine and the comparison of this method with GC–MS techniques and gas chromatography–high resolution mass spectrometry (GC–HRMS) techniques. Urine samples were hydrolyzed with β-glucuronidase, extracted with methyl tert-butyl ether and dried under nitrogen. The derivative reagent was N-methyl-N-(trimethylsilyl)-trifluoroacetamide with NH4I and was analyzed by GC–MS, GC–MS-MS and GC–HRMS. A validation study was conducted by GC–MS-MS. The analyses of clenbuterol using different mass spectrometric techniques were compared. The limit of detection (LOD) for clenbuterol in human urine was 2 ng/mL by GC–MS (selected ion monitoring mode: SIM mode), 0.06 ng/mL by GC–HRMS and 0.03 ng/mL by GC–MS-MS, respectively, while the LOD by GC–HRMS was 0.06. With GC–MS-MS, the intra-assay and inter-assay precisions were less than 15%, the recoveries were 86 to 112% and the linear range was 0.06 to 8.0 ng/mL. The GC–MS under SIM mode can be used as a screening tool to detect clenbuterol at trace levels in human urine. The GC–MS-MS and GC–HRMS methods can confirm clenbuterol when its concentration is below 2 ng/mL. The results demonstrate that the GC–MS-MS method is quite sensitive, specific and reliable for the detection of clenbuterol in doping analysis.

This publication has 18 references indexed in Scilit: