Mechanical Interferometry Imaging for Creep Modeling of the Cornea
Open Access
- 1 October 2011
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 52 (11) , 8420-8424
Abstract
Purpose.: A novel nanoindentation technique was used to biomechanically characterize each of three main layers of the cornea by using Hertzian viscoelastic formulation of creep, the deformation resulting from sustained-force application. Methods.: The nanoindentation method known as mechanical interferometry imaging (MII) with Results.: For all three layers, displacement measurements were highly repeatable and were well predicted by Hertzian models. Although short- and long-term stiffnesses of the endothelium were highest of the three layers at 339.2 and 20.2 kPa, respectively, both stromal stiffnesses were lowest at 100.4 and 3.6 kPa, respectively. Stiffnesses for the epithelium were intermediate at 264.6 and 12.2 kPa, respectively. Conclusions.: Precise, repeatable measurements of corneal creep behavior can be conveniently obtained using MII at mechanical scale as small as one cell thickness. When interpreted in analytical context of Hertzian viscoelasticity, MII technique proved to be a powerful tool for biomechanical characterization of time-dependent biomechanics of corneal regions.Keywords
This publication has 35 references indexed in Scilit:
- Characterization of Ocular Tissues Using Microindentation and Hertzian Viscoelastic ModelsInvestigative Ophthalmology & Visual Science, 2011
- Determining the mechanical properties of human corneal basement membranes with atomic force microscopyJournal of Structural Biology, 2009
- Full-field deformation of bovine cornea under constrained inflation conditionsBiomaterials, 2008
- Assessment of the Biomechanical Properties of the Cornea with the Ocular Response Analyzer in Normal and Keratoconic EyesInvestigative Ophthalmology & Visual Science, 2007
- Spherical indentation load-relaxation of soft biological tissuesJournal of Materials Research, 2006
- Application of structural analysis to the mechanical behaviour of the corneaJournal of The Royal Society Interface, 2004
- Spherical Indentation Creep Following Ramp LoadingMRS Proceedings, 2004
- A microstructurally-based finite element model of the incised human corneaJournal of Biomechanics, 1991
- Corneal elasticity and ocular rigidity in normal and keratoconic eyesActa Ophthalmologica, 1988
- The mechanical properties of the rabbit and human corneaJournal of Biomechanics, 1986