Sensor Based on Aptamer Folding to Detect Low-Molecular Weight Analytes
Authors:
- Alina OsypovaAOAlina Osypova
- Dhruv ThakarDTDhruv Thakar
- Jérôme DejeuJDJérôme Dejeu
- Angéline Van der HeydenAHAngéline Van der Heyden
- Galina V. DubachevaGDGalina V. Dubacheva
- Ralf P. RichterRRRalf P. Richter
- Eric DefrancqEric Defrancq
- Nicolas SpinelliNSNicolas Spinelli
- Liliane Coche-GuérenteLCLiliane Coche-Guérente
- 30 June 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (15) , 7566-7574
Abstract
Aptamers have emerged as promising biorecognition elements in the development of biosensors. The present work focuses on the application of quartz crystal microbalance with dissipation monitoring (QCM-D) for the enantioselective detection of a low molecular weight target molecule (less than 200 Da) by aptamer-based sensors. While QCM-D is a powerful technique for label-free, real-time characterization and quantification of molecular interactions at interfaces, the detection of small molecules interacting with immobilized receptors still remains a challenge. In the present study, we take advantage of the aptamer conformational changes upon the target binding that induces displacement of water acoustically coupled to the sensing layer. As a consequence, this phenomenon leads to a significant enhancement of the detection signal. The methodology is exemplified with the enantioselective recognition of a low molecular weight model compound, L-tyrosinamide (L-Tym). QCM-D monitoring of L-Tym interaction with the aptamer monolayer leads to an appreciable signal that can be further exploited for analytical purposes or thermodynamics studies. Furthermore, in situ combination of QCM-D with spectroscopic ellipsometry unambiguously demonstrates that the conformational change induces a nanometric decrease of the aptamer monolayer thickness. Since QCM-D is sensitive to the whole mass of the sensing layer including water that is acoustically coupled, a decrease in thickness of the highly hydrated aptamer layer induces a sizable release of water that can be easily detected by QCM-D.Keywords
Funding Information
- Directorate-General for Research and Innovation (PCIG09-GA-2011-293803)
- Fondation Nanosciences
- Institut de Chimie Mol?culaire de Grenoble (2607)
- Agence Nationale de la Recherche (ANR-10-blan-1517, ANR-11-LABX-0003-01)
This publication has 40 references indexed in Scilit:
- Engineering DNA aptamers for novel analytical and biomedical applicationsChemical Science, 2011
- Acoustic Characterization of Nanoswitch Structures: Application to the DNA Holliday JunctionNano Letters, 2010
- Label-Free Detection of Clustering of Membrane-Bound ProteinsAnalytical Chemistry, 2010
- Noncompetitive Fluorescence Polarization Aptamer-based Assay for Small Molecule DetectionAnalytical Chemistry, 2009
- Applications of Aptamers as SensorsAnnual Review of Analytical Chemistry, 2009
- Shear acoustic wave biosensor for detecting DNA intrinsic viscosity and conformation: A study with QCM-DBiosensors and Bioelectronics, 2008
- Viscoelastic, mechanical, and dielectric measurements on complex samples with the quartz crystal microbalancePhysical Chemistry Chemical Physics, 2008
- Aptamer-based biosensorsTrAC Trends in Analytical Chemistry, 2008
- Conformational chemistry of surface-attached calmodulin detected by acoustic shear wave propagationMolecular BioSystems, 2006
- Protein Adsorption Kinetics Drastically Altered by Repositioning a Single ChargeJournal of the American Chemical Society, 1995