Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6–10 years follow-up
Authors:
Open Access
- 30 August 2008
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (12) , 1379-1386
Abstract
A flattened cup was designed to create a more physiological load transfer to the pelvic bone compared to hemispherical cups, and to allow more bone contact compared to low-profile’ spherical cups. To investigate these theoretical advantages and the potential influence of the quality of the acetabular bone, a clinical study was performed in patients with osteoarthritis (OA) and inflammatory arthritis (IA). The aims of the study were (1) to evaluate the fixation of the cup, postoperatively and later when osseous integration should have taken place, (2) to assess perioperative complications such as acetabular fractures and (3) to monitor the polar gap, a potential risk factor for osteolysis. A prospective study was performed on all consecutive OA and IA patients with an indication for primary total hip arthroplasty (THA). Three hundred and nine OA patients (340 hips) and 65 IA patients (76 hips) were included. The acetabular component was the flattened press-fit EPF-PLUS® cup, the femoral component the tapered cementless Zweymueller SL-PLUS® stem. All revisions and complications were recorded. Clinical and radiographical evaluation was performed on regular basis during 6–10 years. The incidence of early loosening of the cup was 0 out of 340 in the OA group and 1 out of 76 in the IA group. The incidence of acetabular fractures was 7 out of 340 in the OA group and 3 out of 76 in the IA group. Failure rate for the acetabular component due to aseptic loosening or osteolysis after 6–10 years was 0% in the OA group and 4.8% in the IA group. In all cases available for follow-up the polar gap had disappeared and full osseous integration had taken place in both the groups. This study shows that the flattened press-fit acetabular component creates adequate initial mechanical stability to allow osseous integration and that the cup can be safely used in both OA and IA patients. However, after 6–10 years, in the IA group failure of the cup due to aseptic loosening occurred once and failure due to osteolysis occurred three times, while these type of failures did not occur in the OA group.Keywords
This publication has 22 references indexed in Scilit:
- Charnley low-frictional torque arthroplasty in young rheumatoid and juvenile rheumatoid arthritis: 292 hips followed for an average of 15 yearsActa Orthopaedica, 2007
- High survival rate of hydroxyapatite-coated hip prostheses100 consecutive hips followed for 10 yearsActa Orthopaedica, 2004
- Cementless acetabular replacement in patients with rheumatoid arthritisA 6- to 14-year prospective studyThe Journal of Arthroplasty, 2003
- The effect of interfacial parameters on cup–bone relative micromotionsJournal of Biomechanics, 2001
- Acetabular defect classification and surgical reconstruction in revision arthroplastyThe Journal of Arthroplasty, 1994
- Periarticular bone in rheumatoid arthritis versus arthrosis: Histomorphometry in 103 hip biopsiesActa Orthopaedica, 1994
- Stability of press-fit acetabular cupsThe Journal of Arthroplasty, 1992
- Osteologic standardization of human coxarthrosis using histomorphometry and its relevance for HIP alloarthroplastyPathology - Research and Practice, 1992
- Juxtaarticular bone loss in experimental inflammatory arthritisJournal of Orthopaedic Research, 1988
- Socket loosening after hip arthroplasty: Radiographic observations in 241 cases up to 15 yearsActa Orthopaedica, 1986