Effects of miniscrew location on biomechanical performances of bone-borne rapid palatal expander to midpalatal suture: A finite element study
- 6 August 2022
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 107 (1) , 103872
Abstract
This study investigated the effects of miniscrew location on biomechanical performance of bone-borne rapid palatal expander (B-RPE) to midpalatal suture, using finite element (FE). Three cases of B-RPE with different miniscrew locations (3 and 6 mm from midpalatal suture and palatal interdental site) were simulated activations in partly ossified midpalatal suture maturation. This study compared the expansion amount and pattern along the suture line. Equivalent von Mises (EQV) stresses at appliance, miniscrew, midpalatal sutures, and elastic strain at the bone around miniscrew were evaluated. In all cases, they could not break the midpalatal suture of palatine bone. However, midpalatal suture at the maxilla was expanded. The expansion amount and unparallel expanding pattern were increased when miniscrews were positioned away from the suture. The interdental miniscrew position extended the suture more than the other 2 cases, but the pattern was unparallel. When the miniscrews were positioned away from the suture, the EQV stress at the appliance and elastic strain at the bone around the miniscrew were reduced. In the case of the palatal interdental miniscrew, all parameters were of lower magnitude. All cases could expand the partly ossified midpalatal suture maturation. The distance between the midpalatal suture and the miniscrew influenced appliance EQV stress, elastic strain at the bone around the miniscrew, and expansion characteristics.Keywords
Funding Information
- Faculty of Dentistry Research Fund and Thammasat University Research Unit in Dental Biomechanics
This publication has 26 references indexed in Scilit:
- Evaluation of alveolar bone loss following rapid maxillary expansion using cone-beam computed tomographyThe Korean Journal of Orthodontics, 2013
- Stress distribution and displacement by different bone-borne palatal expanders with micro-implants: a three-dimensional finite-element analysisEuropean Journal of Orthodontics, 2012
- Factors affecting stresses in cortical bone around miniscrew implantsThe Angle Orthodontist, 2012
- Changes in stress distribution of orthodontic miniscrews and surrounding bone evaluated by 3-dimensional finite element analysisAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2011
- Cortical bone thickness at common miniscrew implant placement sitesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2011
- Alveolar ridge dimensions in maxillary posterior sextants: a retrospective comparative study of dentate and edentulous sites using computerized tomography dataClinical Oral Implants Research, 2011
- Maxillary expansion in customized finite element method modelsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Abfraction: separating fact from fictionAustralian Dental Journal, 2009
- Factors affecting the clinical success of screw implants used as orthodontic anchorageAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Periodontal effects of rapid maxillary expansion with tooth-tissue-borne and tooth-borne expanders: A computed tomography evaluationAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006