A Comparison of Direct Heating During Radiofrequency and Microwave Ablation in Ex Vivo Liver
- 10 May 2012
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (2) , 505-511
Abstract
Purpose This study was designed to determine the magnitude and spatial distribution of temperature elevations when using 480 kHz RF and 2.45 GHz microwave energy in ex vivo liver models. Methods A total of 60 heating cycles (20 s at 90 W) were performed in normal, RF-ablated, and microwave-ablated liver tissues (n = 10 RF and n = 10 microwave in each tissue type). Heating cycles were performed using a 480-kHz generator and 3-cm cooled-tip electrode (RF) or a 2.45-GHz generator and 14-gauge monopole (microwave) and were designed to isolate direct heating from each energy type. Tissue temperatures were measured by using fiberoptic thermosensors 5, 10, and 15 mm radially from the ablation applicator at the depth of maximal heating. Power delivered, sensor location, heating rates, and maximal temperatures were compared using mixed effects regression models. Results No significant differences were noted in mean power delivered or thermosensor locations between RF and microwave heating groups (P > 0.05). Microwaves produced significantly more rapid heating than RF at 5, 10, and 15 mm in normal tissue (3.0 vs. 0.73, 0.85 vs. 0.21, and 0.17 vs. 0.09 °C/s; P < 0.05); and at 5 and 10 mm in ablated tissues (2.3 ± 1.4 vs. 0.7 ± 0.3, 0.5 ± 0.3 vs. 0.2 ± 0 °C/s, P < 0.05). The radial depth of heating was ~5 mm greater for microwaves than RF. Conclusions Direct heating obtained with 2.45-GHz microwave energy using a single needle-like applicator is faster and covers a larger volume of tissue than 480-kHz RF energy.Keywords
This publication has 24 references indexed in Scilit:
- Microwave ablation of the liver: a description of lesion evolution over time and an investigation of the heat sink effectPathology, 2011
- A Review of Coaxial-Based Interstitial Antennas for Hepatic Microwave AblationCritical Reviews in Biomedical Engineering, 2006
- Radiofrequency Ablation: Importance of Background Tissue Electrical Conductivity—An Agar Phantom and Computer Modeling StudyRadiology, 2005
- Mechanisms of Focal Heat Destruction of Liver TumorsJournal of Surgical Research, 2005
- Radiofrequency versus Microwave Ablation in a Hepatic Porcine ModelRadiology, 2005
- Influence of Large Peritumoral Vessels on Outcome of Radiofrequency Ablation of Liver TumorsJournal of Vascular and Interventional Radiology, 2003
- Effect of Vessel Size on Creation of Hepatic Radiofrequency Lesions in PigsAmerican Journal of Roentgenology, 2002
- Radiofrequency Ablation of Porcine Liver In VivoAnnals of Surgery, 1998
- Percutaneous Radiofrequency Tissue Ablation: Does Perfusion-mediated Tissue Cooling Limit Coagulation Necrosis?Journal of Vascular and Interventional Radiology, 1998
- The UHF and microwave dielectric properties of normal and tumour tissues: variation in dielectric properties with tissue water contentPhysics in Medicine & Biology, 1980